INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
• Where there is high-frequency or wireless equipment.
WARNING:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
• Use the correct power (voltage and frequency) indicated on the unit to operate the air conditioner and use only fuses or
breakers with specified capacity. Do not use pieces of wire instead of fuses.
WARNING:
• The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.
• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
• The unit should be installed by licensed contractor according to local code requirements.
The installation location of the outdoor unit should be at least
10 ft. away from the antennas for TV sets, radios, etc. In areas
where the reception is weak, provide greater space between
the outdoor unit and the antenna of the affected device if op-
eration of the air conditioner interferes with radio or TV recep-
tion.
Inverter-type
To prevent the effects
fluorescent lamp
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent the
picture
distortion or
3 ft.
or more
the noise.
3 ft.
Cordless
or more
phone or
Portable
phone
Radio
* The required space depends on the type of outdoor unit.
Wall, etc.
Well-
ventilated
dry place
4 in. or
more
20 in. or
more
TV
10 ft.
or more

Advertisement