Mitsubishi MSZ-SF15VA Installation Manual
Mitsubishi MSZ-SF15VA Installation Manual

Mitsubishi MSZ-SF15VA Installation Manual

Split-type
Hide thumbs Also See for MSZ-SF15VA:

Advertisement

Quick Links

SPLIT-TYPE AIR CONDITIONERS
MSZ-SF15VA
MSZ-SF20VA

INSTAllATIoN MANuAl

• This manual only describes the installation of indoor unit.
When installing the outdoor unit, refer to the installation manual of outdoor unit.
INSTAllATIoNSANlEITuNG
• Diese Anleitung beschreibt nur die Installation des Innengerätes.
Zur Installation des Außengerätes lesen Sie bitte die Installationsanleitung des
Außengerätes.
NoTICE D'INSTAllATIoN
• Cette notice ne décrit que l'installation de l'unité interne.
Pour l'installation de l'unité externe, se reporter à la notice d'installation de l'appareil.
INSTAllATIEHANDlEIDING
• Deze handleiding beschrijft alleen de installatie van de binnenunit.
Raadpleeg de installatiehandleiding van de buitenunit wanneer u deze installeert.
MANuAl DE INSTAlACIÓN
• En este manual sólo se describe la instalación de la unidad interior.
Para instalar la unidad exterior, consulte el manual de instalación de dicha unidad.
MANuAlE PER l'INSTAllAZIoNE
• Questo manuale descrive solo l'installazione dell'unità interna.
Per l'installazione dell'unità esterna, fare riferimento al manuale per l'installazione
dell'unità esterna.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
• Στο παρόν εγχειρίδιο περιγράφεται μόνο η εγκατάσταση της μονάδας εσωτερικού χώρου.
Για την εγκατάσταση της μονάδας εξωτερικού χώρου, ανατρέξτε στο εγχειρίδιο εγκατάστασης
της μονάδας εξωτερικού χώρου.
MANuAl DE INSTAlAÇÃo
• Este manual descreve apenas a instalação da unidade interior.
Quando proceder à instalação da unidade exterior, consulte o manual de instalação
da unidade exterior.
INSTAllATIoNSHÅNDBoG
• Denne håndbog beskriver kun, hvordan indendørsenheden installeres.
Vedrørende installation af udendørsenheden henvises til installationshåndbogen
for udendørsenheden.
INSTAllATIoNSANVISNING
• Denna installationsanvisning beskriver endast installation av inomhusenheten.
Se separat installationsanvisning för utomhusenheten.
TESİS ETME KILAVUZU
• Bu kılavuzda yalnızca iç ünitenin tesisi açıklanmaktadır.
Dış ünite tesis işlemini yaparken dış ünite tesis etme kılavuzuna bakın.
Ръководство за монтаж
• Това ръководство описва само монтажа на вътрешното тяло.
При монтиране на външното тяло вижте ръководството за монтаж на външното тяло.
INSTRUKCJA MONTAŻU
• Niniejsza instrukcja zawiera tylko opis instalacji jednostki wewnętrznej.
W przypadku instalowania jednostki zewnętrznej należy odnieść się do instrukcji
montażu jednostki zewnętrznej.
For INSTALLER
FÜR DEN INSTALLATEUR
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER IL TECNICO INSTALLATORE
ΓΙΑ ΤΟΝ ΤΕΧΝΙΚΟ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖR
TESİSATÇI İÇİN
За ИНСТАЛАТОРА
DLA INSTALATORA
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Dansk
Svenska
Türkçe
Български
Polski

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSZ-SF15VA and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi MSZ-SF15VA

  • Page 1: Installation Manual

    SPLIT-TYPE AIR CONDITIONERS MSZ-SF15VA MSZ-SF20VA INSTAllATIoN MANuAl For INSTALLER English • This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual of outdoor unit. INSTAllATIoNSANlEITuNG FÜR DEN INSTALLATEUR Deutsch • Diese Anleitung beschreibt nur die Installation des Innengerätes. Zur Installation des Außengerätes lesen Sie bitte die Installationsanleitung des Außengerätes. NoTICE D’INSTAllATIoN POUR L’INSTALLATEUR Français • Cette notice ne décrit que l’installation de l’unité interne. Pour l’installation de l’unité externe, se reporter à la notice d’installation de l’appareil. INSTAllATIEHANDlEIDING VOOR DE INSTALLATEUR Nederlands • Deze handleiding beschrijft alleen de installatie van de binnenunit.
  • Page 2: Before Installation

    Required Tools for Installation CONTENTS Phillips screwdriver 4 mm hexagonal wrench Level Flare tool for R410A 1. BEFORE INSTALLATION ........1 This installation manual de- Scale Gauge manifold for R410A 2. INDOOR UNIT INSTALLATION ......3 scribes only for the indoor unit. Utility knife or scissors Vacuum pump for R410A 3. PURGING PROCEDURES, LEAK TEST, AND Refer to the MXZ type manual for 65 mm hole saw Charge hose for R410A TEST RUN ............5 outdoor unit set up. Torque wrench Pipe cutter with reamer 4. RELOCATION AND MAINTENANCE ....5 Wrench (or spanner) 1. BEFORE INSTALLATION 1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY • Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
  • Page 3: Specifications

    1-3. SPECIFICATIONS Pipe size Model Power supply *1 Wire specifications *2 (thickness *3, *4) Indoor unit Outdoor unit Rated Voltage Frequency Breaker capacity Power supply Indoor/outdoor connecting wire Gas / Liquid MSZ-SF15VA 4-core ø9.52 / 6.35 mm – 230 V 50 Hz – – MSZ-SF20VA 1.0 mm (0.8 mm) *1 Connect to the power switch which has a gap of 3 mm *4 Use a copper pipe or a copper-alloy seamless pipe. *8 Insulation material : Heat resisting foam plastic 0.045 or more when open to interrupt the source power phase. *5 Be careful not to crush or bend the pipe during pipe...
  • Page 4: Indoor Unit Installation

    2. INDOOR UNIT INSTALLATION 2-1. FIXING OF INSTALLATION PLATE 2-4. PIPE FORMING AND DRAIN PIPING Pipe Forming • Find a structural material (such as a stud) in the wall and fix installation plate Felt tape (4) (1) horizontally by tightening the fixing screws (2) firmly. • Place the drain hose below the refrigerant piping. Piping tape (G) • Make sure that the drain hose is not heaved or • To prevent installation plate (1) from vibrating, be sure to install the fixing screws Liquid pipe snaked. in the holes indicated in the illustration. For added support, fixing screws may • Do not pull the hose when applying the tape. Gas pipe also be installed in other holes. • When the drain hose passes the room, be sure • When the knockout is removed, apply vinyl tape to the knockout edges to to wrap insulation material (obtainable at a store) Indoor/outdoor unit prevent damaging the wires.
  • Page 5: Flaring Work

    2-5. FLARING WORK 2-7. INSULATION AND TAPING 1) Cut the copper pipe correctly with pipe cutter. 1) Cover piping joints with pipe cover. (Fig. 1, 2) 2) For outdoor unit side, surely insulate every piping including valves. Copper 2) Completely remove all burrs from the cut 3) Using piping tape (G), apply taping starting from the entry of outdoor unit. pipe cross section of pipe. (Fig. 3) • Stop the end of piping tape (G) with tape (with adhesive agent at- Fig. 1 • Put the end of the copper pipe to tached). downward direction as you remove burrs • When piping have to be arranged through above ceiling, closet or where in order to avoid to let burrs drop in the the temperature and humidity are high, wind additional commercially No good Good piping. sold insulation to prevent condensation. 3) Remove flare nuts attached to indoor and 2-8.
  • Page 6: Auto Restart Function

    3. PURGING PROCEDURES, LEAK TEST, AND TEST RUN 3-3. AUTO RESTART FUNCTION 3-1. PURGING PROCEDURES AND LEAK TEST This product is equipped with an auto restart function. When the power Refer to the procedures indicated in the installation manual of the outdoor unit. 3-2. TEST RUN supply is stopped during operation, such as during blackouts, the function automatically starts operation in the previous setting once the power supply is 1) Insert power supply plug into the power outlet resumed. (Refer to the operating instructions for details.) and/or turn on the breaker. 2) Press the E.O. SW once for COOL, and twice Caution: for HEAT operation. Test run will be performed • After test run or remote signal reception check, turn off the unit with the E.O. for 30 minutes. If the left lamp of the operation SW or the remote controller before turning off the power supply. Not doing indicator blinks every 0.5 seconds, inspect the so will cause the unit to start operation automatically when power supply is indoor/outdoor unit connecting wire (A) for mis- resumed. wiring. After the test run, emergency mode (set To the user temperature 24ºC) will start.
  • Page 7 This product is designed and intended for use in the residential, commercial and light-industrial environment. HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y083H03...

This manual is also suitable for:

Msz-sf20va

Table of Contents