Direct Circulation Baseboard Installation
Baseboard heaters, as either the main source of heat or
as supplements to forced-air or boiler applications are
easily plumbed into the water lines from the outdoor
furnace. Fig. 27 and 28 illustrate direct circulation
baseboard installation examples.
Fig. 27
NOTE
Outdoor furnace water temp
setpoint should be set at
185˚F (85˚C) minimum.
Fig. 28
NOTE
Outdoor furnace water temp
setpoint should be set at
185˚F (85˚C) minimum.
Section 1 - Furnace Installation
This horizontal assembly
must not exceed a height
of 4 inches (10 cm) above
top of water heater.
This horizontal assembly
must not exceed a height
of 4 inches (10 cm) above
top of water heater.
CAUTION
This outdoor furnace is not intended to be the
only source of heat.