Pioneer WYC009AMFI20 Service Manual page 27

Wyc series single zone split 3d dc inverter+heat pump
Table of Contents

Advertisement

Enquiry
Display value
information
T1,T2,T3,T4,
-1F,-1E,-1d,-1c,-
T2B,TP,TH,
1b,-1A
Targeted
-19—99
Frequency,
A0,A1,...A9
Actual
b0,b1,...b9
Frequency
c0,c1,...c9
d0,d1,...d9
E0,E1,...E9
F0,F1,...F9
Indoor fan
0
speed
1,2,3,4
/Outdoor fan
speed
14-FF
EXV opening
0-FF
angle
Compressor
0-FF
continuous
running time
Causes of
0-99
compressor
stop.
Reserve
0-FF
Meaning
-25,-24,-23,-22,-21,-2
0
-19—99
100,101,...109
110,111,...119
120,121,...129
130,131,...139
140,141,...149
150,151,...159
OFF
Low speed, Medium
speed, High speed,
Turbo
Actual fan
speed=Display value
turns to decimal
value and then
multiply 10. The unit
is RPM.
Actual EXV opening
value=Display value
turns to decimal
value and then
multiply 2.
0-255 minutes
For the detailed
meaning, please
consult with engineer
25
Remark
1. All the displaying temperature is actual
value.
2. All the temperature is °C no matter what
kind of remote controller is used.
3. T1,T2,T3,T4,T2B display range:-25~70,
TP display range:-20~130.
4. Frequency display range: 0~159HZ.
5. If the actual value exceeds the range, it
will display the maximum value or minimum
value.
For some big capacity motors.
For some small capacity motors,
display value is from 14-FF(hexadecimal),
the corresponding fan speed range is from
200-2550RPM.
If the actual value exceeds the
range, it will display the maximum
value or minimum value.
Decimal display