Table 4–1. Configure Panel controls and descriptions.
Control
Pipeline Identity
Name
App (firmware version)
Loader (version)
CPLD Version
FPGA
Serial Number
Network
Self-Assigned
DHCP
Static
IP Address
Mask
Gateway
Security
Password
Confirm Password
74-0085-05
Description
Editable field. Default for Pipeline SC: Pipeline-<XXXX>, where XXXX is
the serial number printed on the bottom of the Pipeline.
Default for Pipeline Quad: PipelineQuadXXXX_N where N is the device
number 1 through 4).
To change the name, enter a new name, and click Save Changes. The
name is updated in the Pipeline, and is reflected in the Bonjour panel.
Limit: 255 characters.
If you enter a friendly name that already exists, Pipeline adds (1), (2,), as
necessary to maintain uniqueness.
For best naming practices, you should identify the Pipeline model (SC or
Quad), uniquely name it, and, in the case of the Quad, refer to the
channel number. For example, PipelineQuad_Prod7_Channel2.
This displays the Pipeline's firmware version number, composed of
<Major Version>,<Minor Version><Build Number>,<Channel Number
Identifier>. For example: 1,5,33165,00 indicates Version 1.5, Build
33165, channel 0. On Pipeline SC, the channel number ID is always 0.
Upgrades are identified by major version and minor version numbers:
1.5, for example.
This displays the Pipeline's boot loader version number, also composed
of <Major Version>,<Minor Version><Build Number>,<Channel Number
Identifier>.
CPLD chip version number on the Pipeline, for Telestream use.
FPGA chip version number on the Pipeline, for Telestream use.
Four digit serial number of the device, not changeable.
When changing the IP address, you should click Save Changes to
update the Pipeline, then close Internet Explorer or Safari. Wait about 30
seconds, then restart your Web browser and log back on. If you don't,
your Control application will behave incorrectly, and Pipeline Direct will
periodically display an error: "Can't communicate with Pipeline".
Select to utilize the default link-local IP address, generated based on the
Pipeline's serial number; incremented on Pipeline 2, 3, and 4 on Quad.
Select when you want your DHCP server to assign an IP address.
Select to use the IP address, subnet mask, & gateway, entered manually.
Enter the IP address assigned by your network administrator.
Enter the subnet mask assigned by your network administrator.
Enter the gateway address provided by your network administrator.
Editable field. No password is assigned by default. (Username is always
administrator.) Limited to 15 characters; standard HTTP password rules
apply. May be empty to disable authentication.
Editable field. Enter second time to confirm.
Using the Configure Panel
Pipeline User's Guide
41