english
Filling
To ensure optimal, trouble-free functioning of your EHEIM professionel 3 external filter, we
recommend that you use original EHEIM filter materials. Only they are designed precisely for
use with the EHEIM external filter, provide an ideal surface for purifying bacteria to colonise and
ensure clean, healthy aquarium water. You can buy the right media set for the EHEIM professionel
3 from your pet shop dealer, order number 2520800.
10
Fill the bottom filter insert with EHFIMECH to just below the edge. Fill the second and third
filter insert to just below the edge with SUBSTRAT pro.
Attention:
properly.
11
Next, rinse the filter medium in the filter insert under running water, mixing thoroughly at
the same time, until no cloudiness is visible in the water.
12
Insert the filter insert filled with EHFIMECH at the bottom of the filter container and press
down firmly onto the base runners.
13
Insert the second and third filter inserts (both filled with SUBSTRAT pro) after rinsing in the same
way. Push the handles back in and make sure that all filter inserts lie flush on top of each other.
14
Next, lay the white filter pad on the top filter insert so that it is placed on the pushed-in handle.
Attention:
-
Place the lattice screen cover on the white filter pad.

Prefilter

Function: The prefilter collects coarse dirt from the aquarium water so that the water that flows
through the filter inserts has been pre-filtered. This substantially reduces the amount of dirt that
reaches the filter inserts and guarantees highly efficient biological decomposition of pollutants
and a long service life. The prefilter can easily be removed. To make interim cleaning even
easier, the scope of delivery includes a dish for transporting the prefilter.
15
Insert prefilter with blue filter pad in the filter container so that that the overflow area is
above the partition.
Note:
The priming system only functions when the prefilter is empty.

Close filter, insert safety adapter

16
Check that the gasket fits properly on the pump head and the sealing ring fits properly on
the prefilter and remove any soiling. Check for soiling on the sealing surface on the upper
edge of the container, clean if necessary and grease lightly with EHEIM Care Spray, Order
No. 400 100 0.
-
Place pump head on filter container and close all four clips.
17
Push safety adapter into the pump head, applying light pressure, until it engages with
anaudible CLICK. The shut-off lever must be in the OFF position to insert the adapter as
otherwise a safety mechanism prevents it from engaging.
20
Do not overfill as otherwise the filter inserts will not fit on top of each other