Obh532E - Mitsubishi Electric MUZ-GE25VA-a1 Service Manual

Split-type air conditioners
Table of Contents

Advertisement

PERFORMANCE DATA HEAT operation at Rated frequency
MUZ-GE71VA MUZ-GE71VAD
CAPACITY: 8.1 kW
INDOOR
-15
DB (°C)
Q
INPUT
15
4.05
1097
21
3.81
1169
26
3.32
1266
MUZ-GE80VA
CAPACITY: 9.0 kW
INDOOR
-15
DB (°C)
Q
INPUT
15
4.50
1321
21
4.23
1407
26
3.69
1524
MUZ-GE80VA2 MUZ-GE80VAD
CAPACITY: 9.0 kW
INDOOR
-15
DB (°C)
Q
INPUT
15
4.50
1326
21
4.23
1413
26
3.69
1530
NOTE: Q : Total capacity (kW) INPUT : Total power input (W) DB: Dry-bulb temperature WB: Wet-bulb temperature

OBH532E

INPUT: 2110 W
-10
-5
Q
INPUT
Q
INPUT
5.10
1372
6.16
1646
4.86
1477
5.83
1751
4.37
1583
5.43
1857
INPUT: 2540 W
-10
-5
Q
INPUT
Q
INPUT
5.67
1651
6.84
1981
5.40
1778
6.48
2108
4.86
1905
6.03
2235
INPUT: 2550 W
-10
-5
Q
INPUT
Q
INPUT
5.67
1658
6.84
1989
5.40
1785
6.48
2117
4.86
1913
6.03
2244
OUTDOOR WB (°C)
0
5
Q
INPUT
Q
INPUT
7.21
1857
8.26
2005
6.89
1941
7.86
2089
6.40
2047
7.45
2194
OUTDOOR WB (°C)
0
5
Q
INPUT
Q
INPUT
8.01
2235
9.18
2413
7.65
2337
8.73
2515
7.11
2464
8.28
2642
OUTDOOR WB (°C)
0
5
Q
INPUT
Q
INPUT
8.01
2244
9.18
2423
7.65
2346
8.73
2525
7.11
2474
8.28
2652
62
10
15
Q
INPUT
Q
INPUT
9.32
2131
10.29
2194
8.91
2194
9.88
2258
8.51
2300
9.48
2363
10
15
Q
INPUT
Q
INPUT
10.35
2565
11.43
2642
9.90
2642
10.98
2718
9.45
2769
10.53
2845
10
15
Q
INPUT
Q
INPUT
10.35
2576
11.43
2652
9.90
2652
10.98
2729
9.45
2780
10.53
2856
20
Q
INPUT
11.34
2237
10.89
2342
10.53
2427
20
Q
INPUT
12.60
2692
12.11
2819
11.70
2921
20
Q
INPUT
12.60
2703
12.11
2831
11.70
2933

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents