Obh532E - Mitsubishi Electric MUZ-GE25VA-a1 Service Manual

Split-type air conditioners
Table of Contents

Advertisement

MUZ-GE71VA MUZ-GE71VAD
MUZ-GE80VA MUZ-GE80VA2
Refrigerant pipe ø 15.88
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 9.52
(with heat insulator)
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
MUZ-GE25VA
MUZ-GE25VAD
MUZ-GE33VA
MUZ-GE35VA
MUZ-GE35VA2
MUZ-GE35VAD
MUZ-GE42VA
MUZ-GE42VAD
MUZ-GE50VA
MUZ-GE50VA2
MUZ-GE50VAD
MUZ-GE60VA
MUZ-GE60VAD
MUZ-GE71VA
MUZ-GE71VAD
MUZ-GE80VA
MUZ-GE80VA2
MUZ-GE80VAD
Indoor
unit
Max. Height
difference

OBH532E

MUZ-GE80VAD
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Strainer
#100
Stop valve
Capillary tube
ø 4.0 ×ø 2.4 × 100
Refrigerant piping: m
Max. Length
A
20
30
B
Max. Length
A
Muffler
#100
Defrost
thermistor
RT61
Compressor
LEV
Strainer
#100
Refrigerant flow in cooling
Refrigerant flow in heating
Max. Height difference
B
12
15
Outdoor unit
29
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
R.V. coil
heating ON
cooling OFF
Piping size O.D: mm
Gas
9.52
12.7
15.88
Unit: mm
Liquid
6.35
9.52