MUZ-GE50VA MUZ-GE50VA2 MUZ-GE50VAD
Refrigerant pipe ø 12.7
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 6.35
(with heat insulator)
MUZ-GE60VA MUZ-GE60VAD
Refrigerant pipe ø 15.88
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 6.35
(with heat insulator)

OBH532E

Muffler
#100
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Receiver
Stop valve
Capillary tube
(with strainar)
ø 3.6 ×ø 2.4 × 50
Muffler
#100
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Compressor
Strainer
#100
Stop valve
Capillary tube
ø 4.0 ×ø 2.4 × 100
Defrost
thermistor
RT61
Compressor
Outdoor heat
exchanger
temperature
thermistor
RT68
LEV
Strainer
R.V. coil
#100
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Outdoor
heat
exchanger
Defrost
thermistor
RT61
Outdoor heat
exchanger
temperature
thermistor
RT68
LEV
Strainer
R.V. coil
#100
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
28
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Ambient
temperature
thermistor
RT65