en | Safety
Recycling and Disposal:
2015.06 | 3.1 | F.01U.304.912
The power cord must be a three-conductor type (two
current carrying conductors; one ground conductor)
terminated on one end by an IEC 60320 appliance
coupler (for connection to the midspan), and on the
other end by a plug containing a ground (earthing)
contact.
The power cord must be rated for a minimum of 250
VAC RMS operation, with a minimum rated current
capacity of 5 Amps (or a minimum wire gauge of 18
AWG (0.75mm
Midspans installed in Australia require power cords
with a minimum wire gauge of 16 AWG (1.0 mm
A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
midspan to this power outlet.
The AC wall socket-outlet must be near the midspan and
easily accessible. You can remove AC power from the
midspan by disconnecting the AC power cord from either
the wall socket-outlet or the midspan appliance coupler.
The PoE injector "Data In" and "Data & Power Out" ports
are shielded RJ45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets.
Only RJ45 data connectors can be connected to these
sockets.
The Data In and Data & Power Out interfaces are qualified
as SELV (Safety Extra-Low Voltage) circuits according to
IEC 60950-1. These interfaces can only be connected to
SELV interfaces on other equipment.
).