  • Page 1 USER MANUAL WALL MOUNTED FAN COILS SF-51H, SF-68H, SF-85H...
  • Page 2  ...
  • Page 3: User Notice

    This symbol stands for the items should be followed. Thank you for choosing SINCLAIR fan coils, please read this owner's manual carefully before operation and keep it for fucture reference. The products in this manual may be different from the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
  • Page 4: Table Of Contents

    Contents 1. Notices for operation ................1 2. Notices for use..................3 3.Name and function of each part............4 4. Wired Controller Operation (optional) ..........9 5. Emergency operation ..............15 6. Troubleshooting ................18 7. Notices for installation ..............20 8. Installation dimension diagram ............22 9. Install the unit .................23 10.
  • Page 5: Notices For Operation

    Fan Coil Unit Wall Mounted Type 1. Notices for operation Be sure to pull out the power Select the most appropriate Earth: The ground be plug when not using the air connected! tempremature. codictionary for a long time. If not, please ask the qualified person-nel to install.
  • Page 6 Fan Coil Unit Wall Mounted Type Don't insert your hands or stick into the air Don't blow the wind to animals and plants directly. intake or outlet vents. It can cause a bad influence to them. Otherwise it will cause accident. Don't apply the cold wind to the body for a long Don't use the air conditioner for other purposes, time.
  • Page 7: Notices For Use

    Fan Coil Unit Wall Mounted Type 2. Notices for use 2.1 Working principle for cooling Principle: ● The unit absorbs energy from the air indoors and takes the energy away through circulation of cooling water, so as to reduce indoor ambient temperature. Accordingly, the cooler the water, the larger the cooling capacity.
  • Page 8: Name And Function Of Each Part

    Fan Coil Unit Wall Mounted Type Name and function of each part 3.1 The unit Air in Air out The patten in displayer: Cool Wireless (1) Power cable remote control Heat (2) Remote control (3) Front panel Set temp. (4) Filter (5) Guide louver (6) Wall pipe (7) Bind tape...
  • Page 9: Operation Of Wireless Remote Control

    Fan Coil Unit Wall Mounted Type 3.2 Operation of wireless remote control Note: Be sure that there are no obstructions between receiver and remote control; Donot drop or throw the remote control; Don't let any liquid drop into the remote control or leave the remote control under the sunlight or place where is very hot.
  • Page 10 Fan Coil Unit Wall Mounted Type ● LIGHT LIGHT button Press this button to select LIGHT On/Off in the displayer. When the LIGHT On is LIGHT buttonLIGHTset,the mark will be displayed and the indicator light in the displayer will be on. When the LIGHT Off is set, the mark will disappear and the indicator light will be off.
  • Page 11 Fan Coil Unit Wall Mounted Type 3.4 Operation of wireless remote control Note: This is a general remote control, it could be used for multiple types (functions) of air conditioners. For some models without the functions specified here, we preserve the right to not to inform exclusively.
  • Page 12: Changing Batteries And Notices

    Fan Coil Unit Wall Mounted Type (2) Press MODE button, select desired running mode ,or press COOL or HEAT mode to enter the corresponding operation directly. (3) Press + or-button to set the desired temperature. (4) Press FAN button to set fan speed from AUTO, FAN ,LOW MID and HIGH. (5) Press+_ button to select SWING mode.
  • Page 13: Wired Controller Operation (Optional)

    Fan Coil Unit Wall Mounted Type 4. Wired Controller Operation (optional) 4.1 Notice before starting the unit. (1) To ensure the heat exchanging, the air in the fan coil of the unit must be exhausted before using. (2) Before starting the unit , make sure that the cable connection of the fan coil is correct and no sundries in the duct.
  • Page 14 Fan Coil Unit Wall Mounted Type 4.3 Wired Controller Operation 4.3.1 ON/OFF (1) Press “ON/OFF” button this unit will start working. (2) Press “ON/OFF” button again, this unit will stop working. 4.3.2 FAN (1) This fan runs at the following speed: (2) Dry mode: the fan speed will be automatically set to LOW.
  • Page 15 Fan Coil Unit Wall Mounted Type 4.3.7 Energy Saving Setting (Fig.4) (1) In the status of OFF, press the button FAN and ▼ simultaneously for 5seconds, MO DE the SAVE menu will appear and comes to the energy saving settings of cooling and dry (showing SAVE + COOL, for the first time of setting, the initial temperature is 26);then press MODE button, it changes to energy...
  • Page 16 Fan Coil Unit Wall Mounted Type 4.3.9 Malfunction display (Fig.6) If there is a malfunction during the operation code will be showed. It means evaporator sensor malfunction is Fig4. The meaning of other error codes is as below: MO DE FA N SW IN G TI ME R...
  • Page 17 Fan Coil Unit Wall Mounted Type 4.3.10 Sensor setting (Fig.7) Press the “FAN+SWING” button MO DE for 10 seconds in the “OFF ”status to enter the senor setting menu. A code will be displayed on the “ROOM TEMP.” “01”means the indoor unit sensor, and “02”means the wired controller senor, press “▲”and “▼”to chose the senor.
  • Page 18 Fan Coil Unit Wall Mounted Type 4.3.12 Button lock function (Fig.9) Press the “▲” + “▼” button for 5 MO DE seconds, “EE” will appear at ROOM TEMP and the buttons will be locked. Presses the “▲” +“ ▼ ” button for 5 seconds again, the button locked function will be canceled.
  • Page 19: Emergency Operation

    Fan Coil Unit Wall Mounted Type When the functions are locked, the lock function can only be canceled by the long-distance monitor or by pressing MODE+▼ for 5 seconds. The lock function can be kept in the memory after the power-off. 4.3.14 Set the address code of the wired controller (Fig.11) MO DE...
  • Page 20: Clean And Care

    Fan Coil Unit Wall Mounted Type 5.3 Clean and care Caution ● Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. ● Never sprinkle water on the unit for cleaning because it can cause an electric shock. ●...
  • Page 21 Fan Coil Unit Wall Mounted Type 5.4 Clean and care ● Check before use 1. Be sure that nothing obstructs the air outlet and intake vents. 2. Check that whether ground wire is properly connected or not. 3. Check that whether the batteries of air conditioner are changer or not. ●...
  • Page 22: Troubleshooting

    Fan Coil Unit Wall Mounted Type 6. Troubleshooting CAUTION Don’t attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air...
  • Page 23 Fan Coil Unit Wall Mounted Type The unit can not run. Is Temp. setting suitable? Were inlet and outlet vents obstructed? Is filter dirty? Are the windows and doors clothed? Did Fan speed set at low speed? Is there any heat sources in the room? Cooling(Heating) efficiency is not good.
  • Page 24: Notices For Installation

    Fan Coil Unit Wall Mounted Type 7. Notices for installation 7.1 Important Notices 1. The unit installation work must be done by qualified personnel according to the local rules and this manual. 2. Before installing, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts.
  • Page 25: Ground Requirements

    Fan Coil Unit Wall Mounted Type (4) The min. distance from the unit and combustive surface is 1.5m. (5) The appliance shall be installed in accordance with notional wiring regulations. (6) An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
  • Page 26: Installation Dimension Diagram

    Fan Coil Unit Wall Mounted Type 8. Installation dimension diagram Space to the ceiling 15cm Above Space to the wall 15cm Above 15cm Above Space to the wall 300cm 250cm Above Above Air outlet side Space to the floor The dimensions of the space necessary for correct ●...
  • Page 27: Install The Unit

    Fan Coil Unit Wall Mounted Type 9. Install the unit 9.1 Install the rear panel (1) A l w a y s m o u n t t h e Wall Wall Mark on the middle of it rear panel horizontally. Due Gradienter Space Space...
  • Page 28: Install The Connection Pipe

    Fan Coil Unit Wall Mounted Type 9.4 The piping can be lead out from Inlet water side pipe Outlet water side left, left rear. (1) When routing the piping and wiring from Tailing2 the left side of the unit, cut off the tailings from Tailing1 Inlet side piping Outlet side...
  • Page 29: External Water Pipe Connection Sketch

    Fan Coil Unit Wall Mounted Type 11. External water pipe connection sketch 11.1 Pipe connectionsketch Fan coil (Rear view) Two-Way Valve Provided by contract/install Water flow Water outlet (Diameter=12mm) Water inlet (Diameter=12mm) Connection pipe (Provided by contractor / installer) Connection nut Provided by factory Spring washer Washer...
  • Page 30: Check After Installation And Test Operation

    Fan Coil Unit Wall Mounted Type 12. Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop,shake or emit noise. Have you done the water leakage test? It may cause insufficient cooling (heating) capacity.
  • Page 31 Fan Coil Unit Wall Mounted Type 12.2 Installation and Maintenance of Healthy Filter ● Installation Instructions (1) Forcibly pull the panel for a specific anglefrom the two ends of the front panel accordingto the arrow direction. Then pull the air filterdownwards to remove it. (See Fig.20) (2) Mount the healthy filter onto the air filter,(asshown in Fig.
  • Page 32 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd., 1-4 Argyll Street, London W1F 7LD, UK Supplier and technical support: Nepa, spol.s.r.o.