Download Print this page

Sinclair SF2 C4 Series User Manual

Four-pipe cassette, two-pipe cassette, fan coil unit

Advertisement

Quick Links

FOUR-PIPE CASSETTE
TWO-PIPE CASSETTE
FAN COIL UNIT
USER MANUAL
SF2-xxxC4
SF2-xxxC2
AIR CONDITIONING

Advertisement

loading
Need help?

Need help?

Do you have a question about the SF2 C4 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sinclair SF2 C4 Series

  • Page 1 FOUR-PIPE CASSETTE TWO-PIPE CASSETTE FAN COIL UNIT USER MANUAL SF2-xxxC4 SF2-xxxC2 AIR CONDITIONING...
  • Page 2: Important Safety Information

    1. IMPORTANT SAFETY INFORMATION To prevent water leak, contact your dealer. When the system is installed and runs in a small room, it is To prevent injury to the user or other people and property required to keep the concentration of the water, if by any damage, the following instructions must be followed.
  • Page 3: Operation Range

    3. OPERATION RANGE Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. Use the system in the following temperature for safe and It may cause incomplete combuston or deformation of the unit effective operation.
  • Page 4: Adjusting Air Flow Direction

    Maintenance after a long stop period Keep the indoor unit and remote controller at least 1 m away from televisions, radios, stereos, and other similar equipment. (eg. at the beginning of the season) Failing to do so may cause static or distorted pictures. Check and remove everything that might be blocking inlet A dirty air filter will reduce cooling or heating efficiency, please and outlet vents of indoor units .
  • Page 5: Following Symptoms Are Not Air Conditioner Troubles

    7. FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES Re-install the air filter. Install and close the air-in grill in the reverse order of step 1 Symptom 1: The system does not operate and 2 and connect the control box cables to the corresponding terminators of the main body .
  • Page 6: Troubleshooting

    8. TROUBLESHOOTING Symptom 5: Dust comes out of the unit 8.1. Troubles and causes of air conditioner When the unit is used for the first time in a long time. If one of the following malfunctions occur, stop operation, shut This is because dust has gotten into the unit.
  • Page 7 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in table 2) table 2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...
  • Page 8 NO . Malfunction alarm lamp EEPROM failure P71/P72 Model setting error Performance setting error Water temperature exceeds the protection range Protection against freezing T1 sensor error T2A sensor error T2B sensor error Remote shutdown MODEL PARAMETERS MODE:SF2-600C2 Information to identify the model(s)to which the information relation: Item Symbol Value...
  • Page 9 MODE:SF2-1000C2 Information to identify the model(s)to which the information relation: Item Symbol Value Unit Air flow volume 1700 m³/h Cooling capacity Prated,c Heating capacity Prated,h Total electric power input Pelec Sound power level(high speed) contact details MODE:SF2-1200C2 Information to identify the model(s)to which the information relation: Item Symbol Value...
  • Page 10 MODE:SF2-800C4 Information to identify the model(s)to which the information relation: Item Symbol Value Unit Air flow volume 1360 m³/h Cooling capacity Prated,c Heating capacity Prated,h Total electric power input Pelec 0.06 Sound power level(high speed) contact details MODE:SF2-1000C4 Information to identify the model(s)to which the information relation: Item Symbol Value...
  • Page 12 United Kingdom www.sinclair-world.com This product was manufactured in China (Made in China). R E P R E S E N T A T I V E SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic T E C H N I C A L S U P P O R T SINCLAIR Global Group s.r.o.