Fisher FSMED-74HFPL Technical & Service Manual page 19

Table of Contents

Advertisement

9.9.2 Defrosting time
If the temp. difference condition ① is satisfied for less than 40 minutes, this can be regarded as
severe frosting. The defrosting time is 10 minutes.
If the temp. difference condition ② is satisfied for more than 40 minutes, the defrosting time is 6
minutes.
If the temp. difference condition ① is satisfied out of 40 minutes, generally the defrosting time is
6 minutes, after three continuous 6-minute defrost, the fourth should be 10 minutes defrost. The
circulation is as following:
→7.5-minute defrost → 7.5-minute defrost→7.5-minute defrost→10-minute defrost→
9.9.3 Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
A. The defrost time has reached to 7.5 or 10 minutes.
B. The compressor current has reached to I
models.
9.9.4 Defrosting Actions:
Compressor
4-way Valve
Outdoor Fan
Indoor Fan
9.10
Automatic operation mode
9.10.1
The air conditioner automatically selects one of the following operation modes: cooling, heating
or fan only according to the temp. difference between room temp. (TA) and set temp. (TS).
TA—TS
TA—TS>2
-1 ≤TA-TS≤+2
TA-TS<-1
9.10.2
The indoor fan blows automatically in corresponding selected mode.
9.10.3
The motion of indoor fan's blade should accord with the selected operation mode.
9.10.4
One mode should be carried out for at least 15 minutes once selected. If the compressor
cannot start for 15 minutes, reselect the operation mode according to the room temp. and set
temp., or reselect when the set temp. varies.
DEFROST
Defrost 10or 6minutes
45S
40S
10S
Operation mode
Cooling
Fan-only
Heating (air-only for cooling only type)
18
or above, I
differs in different
DEROST
25S
23S

Advertisement