UPC/EAN Security Level
Parameter # 4Dh
MiniScan scanners offer four levels of decode security for UPC/EAN bar codes. Select
higher levels of security for decreasing levels of bar code quality. Increasing security
decreases the scanner's aggressiveness, so choose only that level of security necessary
for the application.
UPC/EAN Security Level 0
This default setting allows the scanner to operate in its most aggressive state, while
providing sufficient security in decoding "in-spec" UPC/EAN bar codes.
UPC/EAN Security Level 1
Select this option if misdecodes occur. This security level eliminates most misdecodes.
*UPC/EAN Security Level 0
(00h)
UPC/EAN Security Level 1
(01h)
Parameter Menus
10-47