3-2. Connection Diagram

WARNING
Using meter in applications where high-fre-
quency output is used may cause poor arc
starting and unreliable meter readings.
8
2
OR
7
12
Figure 3-2. Connection Diagram
READ SAFETY BLOCKS at start of
Section 3 before proceeding.
3
6
4
2
5
11
9
1
Welding Power Source
2
Weld Cable (Customer
Supplied)
See power source Owner's Manual
for proper size cable. Keep cable
length between meter and arc as
short as possible for more accurate
readings.
3
Meter
4
Access Door
5
Shunt Terminal
6
SMAW Electrode Holder
7
GTAW Torch
8
Wire Feeder
Open access door and connect
weld cable from power source to
either shunt terminal. Connect weld
1
cable from electrode holder, torch
or wire feeder to other shunt termi-
2
nal.
4
Close access door.
9
115 VAC Cord/Plug
10 115 VAC Grounded
Receptacle
Connect input power plug to weld-
ing power source or other 115 VAC
receptacle.
11 Voltage Sensing Cord/Clamp
12 Workpiece
Connect voltage sensing clamp to
workpiece.
10
ST-154 610-B / ST-155 327