Section 4 − Installation; Serial Number And Rating Label Location; Specifications; Gun Recommendation Table - Miller Electric SuitCase X-TREME 8 HD Owner's Manual

Wire feeder om-246 828h
Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located inside the cover. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Specifications

Welding
Type of
Power
Input
Source
Power
Type
Constant
Open-Circuit/
Voltage (CV)
Or Constant
Arc Voltage,
Current (CC)
14 − 110
Volts DC
DC Power
Source Only
*Maximum gun length is 10 ft. for solid steel .062 in. wire.

4-3. Gun Recommendation Table

Process
GMAW − Hard or Cored Wires
FCAW − Self-Shielding Wires

4-4. Equipment Connection Diagram

1
2
3
4
5
OM-246 828 Page 12
SECTION 4 − INSTALLATION
Wire Feed
Wire
Speed
Diameter
Range
Range
*Solid Steel:
.023 − 5/64 in.
25 − 780 ipm
(0.6 − 2.0 mm);
(1.3 − 19.8
Stainless Steel:
mpm)
.023 − .052 in.
Depending On
(0.6 − 1.3 mm);
Arc Voltage
Flux Cored:
.030 − 5/64 in.
(0.8 − 2.0 mm)
Input
Max. Wire
Welding
IP
Circuit
Rating
Capacity
Rating
330 Amperes
10 lb (4.5 kg),
At 60%
23
8 in. (203 mm)
Duty Cycle
Bernard Q300 or Q400
Dura-Flux With 12 in. Head Tube
10
8
7
6
Overall
Spool
Dimensions
Length: 18 in.
(457 mm)
Width: 7-1/4 in.
(184 mm)
Height: 12-3/4 in.
(324 mm)
Gun
!
Turn Off wire feeder and
welding power source. Stop
engine
on
generator.
!
Use only with CC/CV DC
Power Sources.
1
Constant Current (CC) or
Constant Voltage (CV)
Welding Power Supply
2
Weld Cable To Feeder
3
Work Cable To Workpiece
Weld cable and work cable connec-
tions to power source (DCEN/
DCEP) are dependant on wire type.
.
Since feeder is not polarity sen-
sitive, there is no need for an
electrode polarity switch.
4
Workpiece
5
Voltage Sensing Clamp
9
Connect voltage sensing clamp to
workpiece.
6
Gun
7
Gun Trigger Receptacle
8
Wire Feeder
9
Gas Hose
10 Gas Cylinder
Use of shielding gas is dependant
on wire type.
.
Shielding gas pressure not to
exceed 100 psi (689 kPa).
Weight
30 lb
(13.6 kg)
welding
Ref. 804 419-A

Advertisement

Table of Contents
loading