7-3. Overload Protection (Honda-Powered Units)

7-4. Adjusting Engine Speed (Kohler-Powered Units)

Top View
TM-499 Page 20
1
3
1
The circuit breaker protects the en-
gine battery charging circuit. A
short circuit or a battery connected
in reverse polarity will trip the circuit
breaker.
Press button to reset breaker.
.
After tuning engine, check engine
speeds. See table for proper no
load speeds. If necessary, adjust
speeds as follows:
2000
150 rpm
Start engine and run until warm.
Weld/Power Speed
Adjustment
3720
50 rpm (60 Hz)
3250
50 rpm (50 Hz)
1
2
Move lever to Run (far right) posi-
tion. To increase speed, turn screw
Tools Needed:
out (counterclockwise) while lightly
pushing lever to the right. To de-
crease speed, turn screw in (clock-
wise).
Idle Speed Adjustment
3
Move lever to idle (far left) position.
To increase idle speed, turn screw
in (clockwise). To decrease idle
speed, turn screw out (counter-
clockwise).
Y Stop engine. Close fuel
Top View
2
Ignition Circuit Breaker
(Electric-Start Models Only)
If breaker continues to open,
check starter solenoid (see en-
gine manual).
Ref. 802 094-A
Throttle Control Lever
Adjustment Screw
Adjustment Screw
valve.
1
802 511-A / Kohler Dwg.