Extension Cord Data - Miller Electric Spectrum 1251 Owner's Manual

Air plasma cutter and ice-100t/tm torch
Hide thumbs Also See for Spectrum 1251:
Table of Contents

Advertisement

4-8. Extension Cord Data

NOTE
Input Power
Phase
Input Voltage
208 V
3
230 V
3
460 V
3
575 V
3
400 V
3
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose − no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
.
A complete Parts List is available at www.MillerWelds.com
When calculating max. cord length, remember to include conductor length from
line disconnect device to input power receptacle.
Fuse Size Or
Circuit Breaker Rating
Hertz
Time-Delay
60
Normal Operating
Time-Delay
60
Normal Operating
Time-Delay
60
Normal Operating
Time-Delay
60
Normal Operating
Time-Delay
50
Normal Operating
Conductor Size
2
60 A
8 AWG
3
80 A
2
60 A
8 AWG
3
70 A
2
30 A
10 AWG
3
35 A
2
20 A
12 AWG
3
30 A
2
25 A
12 AWG
3
35 A
Max. Cord Length
89 ft (27 m)
108 ft (33 m)
284 ft (87 m)
268 ft (82 m)
155 ft (47 m)
OM-201 872 Page 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ice-100tIce-100tm

Table of Contents