Superior DRT40ST40DMN Installation And Operation Instructions Manual page 24

Drt40 multi-view series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT40 Multi View Series Direct Vent Gas Fireplace
J. Assemble vent run to exterior wall - If not
previously measured, locate the center of the
vent at the exterior wall. Prepare an opening
as described in Step B. Assemble the vent
system to point where the terminus of the last
section is within 7" (178 mm) to 11-1/4" (286
mm) inboard of the exterior surface to which
the SV4.5 HT termination is to be attached, see
Figure 42. If the terminus of the last section
is not within this distance, use the telescopic
vent section SV4.5LA, as the last vent section.
For wall thicknesses greater than that shown in
Figure 42, refer to Table 8 on page 25. This table
lists the additional venting components needed
(in addition to the termination and adaptor) for
a particular range of wall thicknesses.
K. Attach termination adaptor - Attach the
adaptor (adaptor - SV4.5RCH - provided with
the termination) to the vent section or telescop-
ing vent section), elbow or appliance collar as
shown in Figure 41 in the same manner as
any SV4.5 vent component (refer to Step E).
L. Install Firestop/Spacer at exterior wall
- When using the square termination, install
SV4.5HF (Secure Vent
®
Flex
) Firestop/Spacer over the opening at the
®
exterior side of the framing, long side up, with
the 3 inch spacer clearance at the top as shown
in Figure 41, and nail into place.
(The Firestop/Spacer may also be installed over
the opening at the interior side of the framing.)
M. Install the desired termination -
1.Installthesquaretermination(SV4.5HT-2)-
For the last step , from outside the exterior
wall, slide the collars of the termination onto
the adaptor (the outer over the outer and the
inner inside the inner) until the termination
seats against the exterior wall surface to which
it will be attached. Orient the housing of the
termination with the arrow pointed upwards.
Secure the termination to the exterior wall. The
horizontal termination must not be recessed
into the exterior wall or siding by more than
the 1-1/4" (32 mm) as shown in Figure 42.
SVHRK Snorkel Cap –The snorkel cap is
designed to be fitted into a basement window
box. The SVHRK cap is for use with flex vent
The vertical distance between the inlet and outlet
of the cap is 28" (711 mm). pipe.
IMPORTANT: The vent termination is hot
while in operation and for a period of
time following the use of the fireplace.
To prevent contact with hot surfaces,
we recommend the use of a Termina-
tion Guard. See Page 41. This can be
purchased at your local dealer.
24
Adaptor
SV4.5RCH
6 to 48" Vent Section,
Telescopic vent section,
Elbow or Appliance Collar
Figure 41
), SF4.5HF (Secure
* Use silicone caulking to seal the top
and sides of the termination, up to the
underlayment, stucco, or masonry
wall surface.
*Caulk
*Caulk
Stucco
Figure 42
Horizontal terminations have been designed to perform in a wide range of weather
conditions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termination
where water from eaves and adjoining rooflines may create a heavy flow of cascading water
onto the termination cap. If the cap must be placed where the possibility of cascading water
exists, it is the responsibility of the builder to direct the water away from the termination
cap by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including the
use of silicone caulking where required.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7"
(178)
12-1/8"
(308 mm)
5-1/8"
(130 mm)
NOTE: Centerline of Vent Piping is NOT
the Same as the Centerline of the
Framed Opening.
Installing the Square Horizontal Termination (SV4.5HT-2)
Interior Surface of
Finished Wall
Maximum Extent of Vent
Siding
Run Sections Relative to
Exterior Surface of Framing
Last Vent Section. Use Tele-
scopic Vent Section (SV4.5LA),
If Necessary
SV4.5HT-2
Square Termination
**For thicknesses greater than 9-1/4"
(235mm), see Table 8.
Venting Connection and Exterior Wall Recessing of the
Horizontal Square Termination (SV4.5HT-2).
Installation and Operation Instructions
To help minimize water infiltration it is
recommended that the Firestop/Spacer
(SV4.5HF) be installed on the exterior
side of the wall.
10-1/2"
(267mm)
See Figures 13 through 16 on Page 11
for Min. Distance to Base of Appliance.
Base of Appliance
Adaptor
SV4.5RCH
900299-00, 08/2015
SV4.5HT-2
Termination
3"
(76 mm)
1"
(25.4 mm)
Maximum Wall Thickness
9-1/4" (235 mm)**
Exterior Surface of Siding
Exterior Surface of
Framing
6" to 9-1/4"
(152 to 235 mm)**
SV4.5HT-2
Square Termination
1-1/4" Maximum Recess of the
Square Termination into Exterior
Finishing Material

Advertisement

Table of Contents
loading

Table of Contents