Fireplace And Framing Specifications - Superior DRT40ST40DMN Installation And Operation Instructions Manual

Drt40 multi-view series direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT40 Multi View Series Direct Vent Gas Fireplace
FIREPLACE FRAMING SPECIFICATIONS
DRT40ST
LibraST
11-3/8
(See-Through)
(See Through)
10-1/2
(267)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
5-1/8
26-3/4
(130)
(679)
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
Dimension A
Secure Vent - 47-1/8 (1197)
***48-1/2
Secure Flex - 47-3/4 (1213)
(1232)
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
**This dimension based on 5/8" drywall.
For 1/2" drywall use 23".
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
Figure 13
DRT40CL (Corner Left)
Figure 15
inches (millimeters)
Minimum Framing
Stud Size is 2x4
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
A
*41-1/2
6-1/4
(1054)
(159)
**22-3/4
(578)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DRT40PF
11-3/8
LibraPF
(289)
(Peninsula)
(Peninsula)
10-1/2
(267)
7
(178)
12-1/8
(308)
7
(178)
5-1/8
(130)
12-1/8
(308)
26-3/4
5-1/8
(679)
(130)
Gas Line
Center of gas line
is 3 in. (76 mm)
up from floor.
Dimension A
Secure Vent - 47-1/8 (1197)
***43-5/8
Secure Flex - 47-3/4 (1213)
(1108)
***Provide Additional Space For Side Vent
Seal Cap If Installing Against A Solid Wall
**This dimension based on 5/8" drywall.
For 1/2" drywall use 23".
*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm)
clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits
easier fireplace installation, if unit is installed after framing is erected.)
Figure 14
DRT40CR (Corner Right)
Figure 16
Installation and Operation Instructions
900299-00, 08/2015
inches (millimeters)
Minimum Framing
Stud Size is 2x4
VENT FRAMING -
TOP VENT WITH
ONE 90º ELBOW
VENT FRAMING -
REAR VENT WITH
NO ELBOWS
A
*41-1/2
6-1/4
(1054)
(159)
**22-3/4
(578)
13