Download Print this page

P-Tronic 40P Instruction Manual page 17

Advertisement

Instruction Manual
11.4 Gouging
In GOUGING position you can remove material with a high efficiency; the
current regulation from 20A up to 100A enables the increasing of the groove's
deep.
Use the following spares on the torch:
Use
4 gas diffuser
14 tip gouging
15 outer nozzle
18 gouging shield cup
P-Tronic 100
code
Z0061AA
Z0092AA
Z0096AA
Z0090AA
12. Use of the equipement:
A)
Connect the earth clamp cable to the work piece
B)
Connect the machine to the power supply net and turn ON the power
switch (8). The green led ON/OFF light on
The yellow led lights up if the torch safety circuit is open
The red led lights up in case of low pressure, wrong voltage supply, or
thermic alarm
C)
With the selector (3), choose the cutting mode
D)
Check the air pressure on the manometer and adjust eventually by using
the pressure reducer knob ( 5) at 5,5-6 bars. Make sure the pressure stays
at the same level during cutting
E)
Set the current value with the knob ( 1 ) according to the basic material tickness
F)
Press the torch trigger: the pilot arc stricks, becoming cutting arc as
soon as you will place the torch on the work
piece. P-TRONIC 100 generator does not work
with high-frequency arc ignition: it uses the no
HF technology with BACK STRIKING system. The
torch can work only if the generator is connected
to the compressed air plant.
G)
The pilot arc stops automatically after about 5 seconds if you do not place
the torch on the work piece
H)
Once the cutting process is terminated release the torch trigger: the air
flow will continue to allow the cooling down of the torch
Warning: never aim the plasma jet towards people or foreign objects !
P-Tronic 40P - 70 - 100
P-Tronic 100
- 13 -
GB

Hide quick links:

Advertisement

loading

This manual is also suitable for:

P-tronic 70P-tronic 100