Download Print this page

P-Tronic 40P Instruction Manual page 10

Advertisement

Instruction Manual
Step 3:
Put the hanger on the handle back
side and fix the reducer using the
GB
proper ring nut
6.2 Use of the equipement:
A)
Connect the earth clamp cable to the work piece
B)
Connect the machine to the power supply net and turn ON the power
switch (position 2. page. 5); the ON/OFF led (position 5 page. 5) light on
C)
Check the air pressure on the manometer as indicated in the previous
paragraph
D)
Set the current value with the knob (1st position fig. pag. 5) according to
the work piece tickness
Filter/Reducer
2
1
IN nipple
6
Supply Cable
Step 4:
The reducer has an "IN" nipple that has
to be connected to the compressed air
net and an "OUT" nipple: provide an 8x6
teflon tube of about 30 cm to link the out-
put nipple "OUT" with the machine air in-
put nipple positioned on the back of the
machine.
P-Tronic 40P
OUT nipple
E)
Press the torch trigger: the pilot arc stricks, becoming cutting arc as
3
4
Teflon
tube
F) The pilot arc stops automatically after about 5 seconds if you do not place
5
the torch on the work piece
G) Check the manometer value and adjust eventually the air pressure
Air Input
H) Once the cutting process is terminated release the torch trigger: the air
flow will continue to allow the cooling down of the torch
Warning: never aim the plasma jet towards people or
foreign objects !
According to the cutting type and mode, the torch must be equipped with suitable
spare parts. The P-Tronic 40
cutting.If you have to make a precision cut on sheet metal and when the spacer (8)
cannot be used, we recommand the Tip 0,9 (5) code Z0050AA. In case of spacer/
stand off cutting, use the Tip 1,0 (6) code Z0051AA.
P-Tronic 40P - 70 - 100
soon as you will place the torch on the work
piece. The P-TRONIC 40 generator does
not work with high-frequency arc ignition:
it uses the no HF technology with BACK
STRIKING system. The torch can work only
if the generator is connected to the com-
pressed air plant
generator enables either the contact or stand-off