List Of Adjustment/Setup Values - Sharp AR-C150 Service Manual

Digital full color copier
Hide thumbs Also See for AR-C150:
Table of Contents

Advertisement

1. List of adjustment/setup values

Simulation
Code
Main Sub.
07
01
Aging setup
08
01
Developing bias output
voltage adjustment
02
Charging/Grid setup
(AR-C100/C150)
Charging/Grid setup
(AR-C160/C250)
06
Transfer voltage
adjustment (Old)
21
01
Maintenance cycle setup
24
05
Reset the developer
counter [YMCK]
07
Reset the OPC drum
correction counter
25
02
Toner concentration
reference control level
26
01
Option setup
Content/Item
A: Aging
B: JAM detection ON/OFF setup
C: Fusing ON/OFF setup
D: Warm-up ON/OFF setup
E: Aging intermittent ON/OFF
setup
F: Developing unit detection
ON/OFF setup
G: Oil check ON/OFF setup
A: (Black)
B: (Cyan)
C: (Magenta)
D: (Yellow)
A: (Black)
B: (Cyan)
C: (Magenta)
D: (Yellow)
A: (Black)
B: (Cyan)
C: (Magenta)
D: (Yellow)
A: Normal (Face) print (Black)
B: Back print (Black)
C: OHP print (Black)
D: Thick paper print (Black)
A: Normal (Face) print (Cyan)
B: Back print (Cyan)
C: OHP print (Cyan)
D: Thick paper print (Cyan)
A: Normal (Face) print (Magenta)
B: Back print (Magenta)
C: OHP print (Magenta)
D: Thick paper print (Magenta)
A: Normal (Face) print (Yellow)
B: Back print (Yellow)
C: OHP print (Yellow)
D: Thick paper print (Yellow)
Maintenance timing (Print quantity)
Maintenance message redisplay
Select the color (Black, Cyan,
Magenta, Yellow)
Select the color (Black, Cyan,
Magenta, Yellow)
(Black)
(Cyan)
(Magenta)
(Yellow)
RADF
DUPLEX / PAPER FEED TRAY
FINISHER
PRINTER
Model
Set range
Default
AR-
AR-
C100
C150
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
OFF
ON/OFF
OFF
0 – 700
325
0 – 700
325
0 – 700
325
0 – 700
325
200 – 900
525
200 – 900
525
200 – 900
525
200 – 900
525
200 – 900
545 (555)
200 – 900
545 (555)
200 – 900
545 (555)
200 – 900
545 (555)
51 – 255
178
51 – 255
178
51 – 255
204
51 – 255
204
51 – 255
164
51 – 255
164
51 – 255
209
51 – 255
187
51 – 255
123
51 – 255
123
51 – 255
167
51 – 255
138
51 – 255
123
51 – 255
123
51 – 255
182
51 – 255
138
0 – 6
4
0 – 2
1
0
0
0 – 255
128
0 – 255
128
0 – 255
128
0 – 255
128
Option/
None
None
Option/
None
None
Option/
None
None
Option/
None
None
14 – 8A
NOTE
AR-
AR-
C160/
C250
C270
The setup data are
not stored.
( ) AR-C160
0. 5K
1. 10K
2. 15K
3. 20K
4. 40K
5. 80K
6. FREE
0. 500 sheets
1. 1000 sheets
2. 2000 sheets
The adjustment value
cannot be entered
directly
The AR-C150 is not
capable of
installation of the
finisher.
Data store
location
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)
EEPROM
(PCU PWB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-c250Ar-c160Ar-c270

Table of Contents