Set room temperature exceeded by large amount
Check
1.
Do radiators get too hot?
2.
Bad choice of location for program-
mer, e.g. outside wall, near window,
in draught, on hollow wall, etc.
3.
1)
See installation instructions
Temperature rises instead of falling
Check
Timer clock (DT 2) incorrectly set
Room temperature too high in Economy mode
Check
Building retains heat well
Incorrect or no modulation
Check
Programmer incorrectly wired
7 181 465 347 (01.07)
Action
yes:
TR 2:
B Decrease setting of "Heating" control
↓2.
↓2.
no:
B Select better installation location
yes:
↓3.
↓3.
no:
B Turn down thermostatic valve(s).n
Action
B Check setting and correct as necessary.
Action
B Set economy temperature lower.
yes:
-or-
B Set earlier start time for Economy mode.
Action
B Check wiring against wiring diagram and correct
as necessary.
Rectifying faults
1)
.
43