C1
flashing.
Fan speed too low
Check
1.
Fan lead connector properly con-
nected?
2.
Fan lead defective?
3.
Fan defective?
4.
The PCB control board is damaged.
7 181 465 347 (01.07)
Action
↓2.
yes:
B Power OFF the appliance.
no:
B Plug in connector.
B Turn ON the appliance.
C6? ↓2.
yes:
B Power OFF the appliance.
B Replace fan lead.
B Turn ON the appliance.
C6? ↓3.
↓3.
no:
B Power OFF the appliance.
yes:
B Plug the connection wire.
B Replace fan.
B Plug the connection wire.
B Turn ON the appliance.
C6? ↓4.
↓4.
no:
B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
Rectifying faults