DigiSense
DT Digital Detectors
Models: Digi-412DTPT
© RISCO Group 10/2011
5IN1264 D
RTTE Compliance Statement
Risco Ltd. hereby declares that this equipment is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC. For the EC Declaration of Conformity please
referto our website: www.riscogroup.com
Clari cation
Digi-412DTPT applicable countries (European version):
AT
BE
CY
CZ
DK
EE
FI
GR
FR
DE
HU
IE
IT
LT
LV
LU
MT
NL
PL
PT
SE
SL
ES
SK
GB
BG
RO
TR
CH
NO
Digi-412DTPT applicable countries (German Version):
AT, CZ, SL, DE, TR, RU, EE
DigiSense FCC compliance Section (US version):
FCC Part 15 Note:
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
receiver.
from that to which the receiver is connected.
FCC Warning:
The manufacturer is not responsible for any radio or TV
authority to operate the equipment.
All rights reserved. No part of this document may be
reproduced in any form without prior written permission
from the publisher.
1
2
Mounting
2
1
1
1
2
4
DIP Switch & Jumper Settings
SW1-1: Pulse 1/2
34k g
lb
ON
1 pulse
EN
2
1
1 impulsion 2 impulsions Pour les lentilles rideau et
FR
1 pulso
SP
CHIUSO
IT
1 impulso
1 pulso
PR
1 impuls
PL
Digi-412DTPT Wide Angle Lens
Top View
6
4
2
0
2
4
6
m
0
2
4
6
10 12
Side View
5
4
3
2
1
0
m
0
2
4
6
10
1
2
2
Wall mounting
Corner mounting
EN
FR
Montage mural
Montage en coin
SP
Montaje en pared
Montaje en rincón
IT
Montaggio su parete piana
Montaggio ad angolo
PR
Montagem na parede
Montagem no canto
PL
2
SW1-2: LED ON/OFF
OFF
Important
ON
For corridor and curtain
2 pulses
LED Enable
EN
lens use only 1 pulse.
FR
LED Activée
SP
LED Activado
Para la lente de pasillo o cortina usar
2 pulsos
sólo 1 pulso.
IT
LED Attivato
APERTO
Per le lenti a tenda o corridoio
2 impulsi
utilizzare solo 1 impulso.
PR
LED Ativado
Para lente de corredor, use apenas
2 pulso
PL
o pulso 1.
2 impulsów
90°
12
3
Terminal Wiring
-
TAMPER
ALARM
12VDC
Terminal Connection
12VDC: Power supply inputs
EN
IT
ALARM: NC Dry Contact switch
TAMPER: NC Dry Contact switch
Connexion
12VDC : alimentation électrique
FR
PR
TAMPER : contact sec NF
Bornes de Conexión
12VDC: Entrada de alimentación
SP
PL
ALARM: Relé de Contacto Seco N.C.
TAMPER: Relé de Contacto Seco N.C.
Schematic of EOL Resistors
EN
5
FR
Sch ma pour R sistances EOL (r sistances de n de ligne)
SP
Esquema de Resistencias de Final de Línea
IT
Schema di collegamento delle resisten e EOL
PR
Diagrama para resistor nal de linha
OFF
PL
Re
stor parametr c ne (EOL)
LED Disable
PANEL DEOL
LED Désactivée
TAMPER
ALARM
LED Desactivado
LED Disattivato
LED Desativado
TAMPER
ALARM
+
Collegamento dei Morsetti
12VDC: Ingresso alimentazione
ALARM: Relè d'allarme NC libero da tensione
TAMPER: Relè di tamper NC libero da tensione
Terminais de Conexão
12VDC: Entrada de alimentação
ALARME: Relé de contato seco NF
TAMPER: Relé de contato seco NF
Pod c enie
12VDC: Zasilanie czujki
ALARM: Zaciski alarmowe NC
J6 - ALARM EOL JUMPERS
No
1K
2.2K
4.7K
5.6K
6.8K
Resistor
(Factor Settings)
J5 - TAMPER EOL JUMPERS
No
1K
2.2K
4.7K
5.6K
6.8K
Resistor
(Factor Settings)
Need help?