Technical Specifications - Stanley STCT224 Instruction Manual

Table of Contents

Advertisement

The pressure vessel quality certificate must be presented to
authorities, in case of inspection. Keep it in a safe place along
CT224
with the instruction manual.
52,8 lbs
24 Kg
70,4 lbs
24,0 in
COMPRESSOR INSPECTION
625 mm
28,7 in
23,0 in
575 mm
27,1 in
Inspect for signs of obvious or concealed freight damage.
12,2 in
270 mm
12,2 in
Report any damage to the delivering freight carrier
immediately. Be sure that all damaged parts are replaced and
any mechanical problems are corrected prior to the operation
of the air compressor. The air compressor serial number is
50 Hz
located on the pump or tank. Please write the serial number in
l/min
60 Hz
the space provided in the service section for future reference.
Lbf/pol
2
bar
Warning! When using electric product, basic
Volumen geom. (L)
safety precautions should always be followed to
50 Hz
reduce risk of fire, electric shock, and personal
Tempo
enchimento
60 Hz
injury.
50 Hz
rpm
60 Hz
FEATURES (Fig. A and B)
HP
Max. HP
1. Air intake filter housing
kW
2. Compressor pump
Max. kW
Tensão (V)
3. Pressure vessel
4. Compressed air outlet (quick coupler), air not regulated
Volume (ml)
5. Compressed air outlet (quick coupler), air regulated
Kg
6. Outlet pressure gauge
Lbs
7. Tank pressure gauge
8. Pressure regulator
9. On/Off switch
10. Safety valve
11. Condensate drain cock
12. Oil drain plug
13. Oil sight glass
14. Dip stick
15. Wheels
CT250
32 Kg
775 mm
325 mm
730 mm
CT224
CT250
140
140
185
185
120
120
8,4
8,4
24
50
1'57
3'55
1'38
3'25
2850
2850
3480
3480
1,5
1,5
2,0
2,0
1,1
1,1
1,5
1,5
120/127 ou 220 120/127 ou 220
220
220
24
32
52,8
70,4
LARANJA
LARANJA

TECHNICAL SPECIFICATIONS

STCT224
STCT224
CT224
CT224
Weight:
Weight:
52,8 lbs
24 Kg
Weight:
52,8 lbs
Height:
Height:
24,0 in
625 mm
Height:
24,0 in
Length:
Length:
23,0 in
575 mm
Length:
23,0 in
Width:
Width:
12,2 in
270 mm
Width:
12,2 in
MODEL
MODEL
MODEL
MODEL
DISPLACEMENT
DISPLACEMENT
DISPLACEMENT
DISPLACEMENT
MAX. PRESSURE
MAX. PRESSURE
MAX. PRESSURE
MAX. PRESSURE
AIR TANK
AIR TANK
AIR TANK
AIR TANK
ROTATION
ROTATION
ROTATION
ROTATION
ELETRIC MOTOR
ELETRIC MOTOR
ELETRIC MOTOR
ELETRIC MOTOR
SINGLE-PHASE
SINGLE-PHASE
SINGLE-PHASE
SINGLE-PHASE
WITH THERMAL
WITH THERMAL
WITH THERMAL
WITH THERMAL
PROTECTOR
PROTECTOR
PROTECTOR
PROTECTOR
OIL
OIL
OIL
OIL
CAPACITY
CAPACITY
CAPACITY
CAPACITY
WEIGHT
WEIGHT
WEIGHT
WEIGHT
COLOR REF:
COLOR REF:
COLOR REF:
COLOR REF:
NOTE: The tank's filling up time varies from ± 10%, according
to the installation.
KEY PARTS AND FUNCTIONS
1. Compressor (pump) Unit.- Pull in and compresses
the atmospheric air.
2. Air Tank.- Stores the compressed air.
3. Electric Motor.- Makes the compressor unit run.
4. Pressure Switch.- Controls the operation of compressor
to avoid that the maximum working pressure is surpassed.
See Installation and Electrical Connection Chapter.
5. Safety Valve.- Automatically exhausts the tank in case
the pressure is above the maximum allowed.
6. Check Valve.- Keeps the compressed air inside the tank
avoiding its return when the compressor unit stops.
7. Drain.- Removes the condensed water that accumulates
inside the tank.
8. Pressure Gauge.- Shows the pressure inside the tank
in psi or bar.
9. Pressure Regulator with Valve.- Used to adjust working
pressure on the indicator panel.
10. Protecting Screen.- Protects the rotating parts.
11. Intercooler.- Carries and cools down the compressed air.
12. Air Filter.- Filters atmospheric air impurities that are
sucked by the compressor.
13. Valve.- Controls the compressed air release, connects
ENGLISH • 5
STCT250
STCT250
CT250
CT250
24 Kg
70,4 lbs
32 Kg
32 Kg
24 Kg
70,4 lbs
32 Kg
625 mm
28,7 in
775 mm
775 mm
625 mm
28,7 in
775 mm
575 mm
27,1 in
325 mm
325 mm
575 mm
27,1 in
325 mm
270 mm
12,2 in
730 mm
730 mm
270 mm
12,2 in
730 mm
STCT224
CTS
STCT224
CTS
50 Hz
140
50 Hz
50 Hz
140
140
50 Hz
140
l/min
l/min
l/min
l/min
60 Hz
185
60 Hz
185
115
psi
120
120
psi
psi
8
bar
8
bar
8,4
8,4
bar
bar
24
24
Geom. Volume (L)
Geom. Volume (L)
24
24
Geom. Volume (L)
Geom. Volume (L)
50 Hz
1'57
Filin
Filin
50 Hz
50 Hz
1'57
1'57
50 Hz
1'57
Filin
Filin
up time
up time
60 Hz
1'38
60 Hz
60 Hz
1'38
1'38
up time
up time
50 Hz
2850
50 Hz
50 Hz
2850
2850
rpm
rpm
50 Hz
2850
rpm
rpm
60 Hz
3450
60 Hz
60 Hz
3480
3480
1,5
1,5
HP
HP
1,5
1,5
HP
HP
2,0
2,0
Max. HP
Max. HP
2,0
2,0
Max. HP
Max. HP
1,1
1,1
kW
kW
1,1
1,1
kW
kW
1,5
1,5
Max. kW
Max. kW
1,5
1,5
Max. kW
Max. kW
230
Voltage (V)
Voltage (V)
120/127 or 230 120/127 or 230
Voltage (V)
Voltage (V)
120/127 or 220 120/127 or 220
120/127 or 220 120/127 or 220
300
300
Volume (ml)
Volume (ml)
220
220
Volume (ml)
Volume (ml)
24
Kg
24
24
Kg
Kg
24
Kg
52,8
Lbs
52,8
52,8
Lbs
Lbs
ORANGE
ORANGE
YELLOW
ORANGE
ORANGE
224
STCT250
STCT250
CT250
140
140
140
140
185
185
115
120
120
8
8
8,4
8,4
50
50
50
50
3'55
3'55
3'55
3'55
3'25
3'25
3'25
2850
2850
2850
2850
3450
3480
3480
1,5
1,5
1,5
1,5
2,0
2,0
2,0
2,0
1,1
1,1
1,1
1,1
1,5
1,5
1,5
1,5
230
300
300
220
220
32
32
32
32
70,4
70,4
70,4
ORANGE
ORANGE
YELLOW
ORANGE
ORANGE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stct250

Table of Contents