Identifying The Failed Hard Drive - Dell Storage Center sc100 Owner's Manual

Expansion enclosure
Table of Contents

Advertisement

An SC120 holds up to 24 drives, which are numbered left to right starting from 0.
Figure 14. SC120 Drive Numbering

Identifying the Failed Hard Drive

To determine which hard drive failed, use the Dell Storage Client.
1.
Click the Hardware tab.
2.
In the Hardware tab navigation pane, select the Storage Center.
3.
In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed hard
drive.
Figure 15. Hardware Alert Identifying the Enclosure with the Failed Hard Drive
4.
In the Hardware tab navigation pane, expand the enclosure identified in the previous step.
5.
Select Disks. The status of each hard drive is displayed in the Disks tab.
6.
Select the failed hard drive. The location of the failed hard drive is displayed in the Disk View tab.
20
Replacing SC100/SC120 Components

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storage center sc120