Panasonic WH-MXF09D3E8 Service Manual page 100

Hide thumbs Also See for WH-MXF09D3E8:
Table of Contents

Advertisement

16.5.25 Outdoor High Pressure Switch Abnormal (F27)
Malfunction Decision Conditions:
During compressor stop, and outdoor high pressure switch is remain opened.
Malfunction Caused:
1
Faulty connector connection.
2
Faulty switch.
3
Faulty outdoor unit PCB (main).
Abnormality Judgment:
Continue for 1 minute.
100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-mxf09d3e8-1Wh-mxf12d9e8Wh-mxf12d9e8-1

Table of Contents