Connections(Example For Cp-9500M2-Eb); Control I/O Terminal Connections; When A Variable Resistor Or Variable Dc Power Supply Unit Is Connected - Toa CP-9500M2-EB Installation And Operating Instructions Manual

9000 series power amplifer dual ch 500w digital mixing amplifier
Table of Contents

Advertisement

14. CONNECTIONS(EXAMPLE FOR CP-9500M2-EB)

14.1. Control I/O Terminal Connections

[Remote volume control terminals 1, 2 (REMT VOL 1, REMT VOL 2)]
Volume of the input or output channels can be remotely adjusted by connecting a variable resistor or variable DC
power supply unit. (The REMT VOL 1 terminal is factory-preset to output 1, and the REMT VOL 2 to output 2.)
Connect a 10 kΩ (linear taper) variable resistor or input the DC voltage of 0 to +10 V as shown below.
The larger the variable resistor resistance, the larger the volume is, and the smaller its resistance, the smaller
the volume is.
Connecting the ZM-9001 Zone Manager adds 6 control inputs and allows the equipped 6 control buttons to
perform the functions assigned for input's or output's channel volume up/down, or Scene memory recall.
Connecting the ZM-9002 Zone Manager adds 1 volume control and 4 control inputs. Volume of the input or
output channels can be remotely adjusted with the volume control, and the 4 control buttons can be assigned
the same functions as those of the ZM-9001.
Note
To avoid interference due to noise, use shielded cables.
[Control input terminals 1 – 4 (IN 1 – 4)]
Connect switch contacts, etc. to these terminals.
Open voltage is 3.3 V, and the short-circuit current is 1 mA or less.
[Control output terminals 1 – 4 (OUT 1 – 4)]
Use these terminals to activate LEDs, relays, and other external equipment.
Maximum operating current is 50 mA, and the maximum applicable voltage is +27 V.

14.1.1. When a variable resistor or variable DC power supply unit is connected

220-240 V
50/60Hz
220
100V/20
500W
100V/20
500W
2
9000 Series Power Amplifier CP-9500M2-EB
Control-I/O connection terminal