A 1/4" diameter slot is provided in the inspection cover plate to take draft readings in the
combustion chamber. See figure 13, on page 12. A 1/4" diameter hole will be required in
the flue pipe between the boiler and barometric damper (if used) to take draft, CO
and temperature readings. Adjust air shutter on oil burner to obtain a "trace" of smoke.
Measure CO
at this point. Increase air adjustment to lower CO
2
percent. Check to insure minimum negative .02 w.c., (water column), "overfire" draft and
zero (0) smoke. If - .02 w.c. "overfire" draft can not be maintained, changes and/or
modifications may be required in the venting or the chimney.
The following tables are provided as a guideline for initial start-up. Final adjustments
MUST be made using combustion instruments as previously mentioned.
BOILER
BURNER
NO.
SFH3100
SFH4125
SFH4150
SFH5200
BOILER
BURNER
NO.
SFH3100
SFH4125
SFH4150
SFH5200
BOILER BURNER
NO.
NO.
SFH3100
AFG
SFH4125
AFG
SFH4150
AFG
SFH5200
AFG
SFH6225
CF375
SFH7275
CF375
* NOTE: model SFH3125 needs pin # 5,SFH6225 needs a head setting of 1, &
SFH7275 needs a head setting of 2.
Nozzle sizes with an H designation are Hago brand, all others are Delevan.
Information in above table uses Beckett model AFG burner for model numbers
SFH365-5200 and Beckett model CF375 for model numbers 6225 and 7275.
CHECK SAFETY CONTROL CIRCUIT after burner adjustments have been made for
satisfactory performance.
OF THE BOILER-BURNER UNIT
RIELLO SETTINGS
AIR
NO.
DAMPER
F-5
3.6
F-5
4.0
F-5
6.0
F-10
5.0
CARLIN SETTINGS
AIR
NO.
DAMPER
EZ-1
.85
EZ-1
1.00-1.10
EZ-1
1.25-1.35
EZ-2
1.75
BECKETT SETTINGS
AIR
AIR
DAMP.
SHUT.
1
5
1
8
2
6
5
5
4
6
4
6
PUMP
PRESS.
150 PSI
150 PSI
150 PSI
150 PSI
PUMP
PRESS.
150 PSI
150 PSI
150 PSI
150 PSI
PUMP
STATIC
PRESS.
DISC
140 PSI
3-3/8U
140 PSI
2-3/4"
140 PSI
2-3/4"
140 PSI
3U
140 PSI
L1
140 PSI
L1
PAGE 13
approximately one (1)
2
TURB.
NOZZLE
FURNISHED
1.0
.85 80W
3.0
1.10 60W
4.0
1.25 60W
0.0
1.75 80B
HEAD
NOZZLE
BAR
FURNISHED
.85-1.00
.85 70B
1.10-1.25
1.10 70B
1.10-1.25
1.25 70B
1.65-1.75
1.75 70B
END
NOZZLE
CONE FURNISHED
F3
.85 80B
F4
1.10 80B
F6
1.25 80B
F12
1.75 70B H
N/A
2.00 45B
N/A
2.25 45B
, smoke
2