SWITCHES

1) Function switch - use to change the information display on the LCD.
2) PTO/IDLE change switch – use to enable PTO/IDLE RPM adjustment function
3) UP/DOWN switch – use to raise or lower PTO/IDLE RPM.

PTO MODE

1) Used to adjust the fixed RPM of PTO.
2) When PTO switch is ON, engine speed will be upgraded 700RPM (initial RPM) .
3) You can adjust the RPM using the UP / DOWN switch.
4) When PTO switch is OFF, engine speed will be returned to the value set for IDLE RPM.
5) Adjustable RPM area : 700 RPM ~ 1900 RPM

IDLE SETTING MODE

1) Used to adjust the IDLE RPM.
2) Operate IDLE switch on Quiescent state.
3) When the switch moved to the UP or DOWN position, RPM value increases or decreases
by increments of 25 RPM.
4) When IDLE switch is OFF, IDLE RPM value will be returned to the initial RPM value.
5) Adjustable RPM area : 600RPM ~ 800RPM.
If you need to change the IDLE RPM value in the range of 600 RPM to 500 RPM, the
value can be changed using the G-SCAN. Contact your Hyundai-SeasAll dealer.