Viking 5 Series Installation Manual page 29

Table of Contents

Advertisement

Water Filter System Specifi cation and Performance
Data Sheet
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a
concentration of less than or equal to the permissible limit for water leaving the system, as specifi ed in
NSF/ANSI 42/53.* (100% safety factors built-in for unmetered usage for health claims only.)
Contaminant
Average
Reduction
Infl uent
Chlorine Taste and
2.0 mg/L
Odor
Nominal Particulate
13,666,667
Class I, >0.5 to <
pts/mL
1.0 µm
Asbestos
96 MF/L
Atrazine
0.010 mg/L
Cyst*
122,500
cysts/L
Lead @ pH 6.5
0.153 mg/L
Lead @ pH 8.5
0.150 mg/L
Lindane
0.002 mg/L
Mercury @ pH 6.5
0.006 mg/L
Mercury @ pH 8.5
0.006 mg/L
Toxaphene
0.015 mg/L
Turbidity
10.8 NTU
*Based on the use of Cryptosporidium parvum oocysts
Operating Specifi cations
Capacity:
Pressure Requirement:
Temperature:
Flow rate:
Check for compliance with the state and local laws and regulations.
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary.
Must be installed and operated in accordance with manufacturer's recommended procedures
and guidelines. Installation instructions, parts and service availability, and standard warranty
are included with the product when shipped. This drinking water system must be maintained
according to manufacturer's instruction, including replacement of fi lter cartridges.
Manufactured by:
3M Purifi cation Inc.
400 Research Parkway
Meriden, CT 06770
NSF Specifi ed
Avg %
Challenge
Reduction
Concentration
2.0 mg/L + 10%
97.5%
At least 10,000
98.9%
particles/mL
7
8
10
to 10
fi bers/L;
>99%
fi bers greater than
10µm in length
0.009 mg/L + 10%
89.3%
Minimum 50,000
99.99%
cysts/L
0.15 mg/L + 10%
99.3%
0.15 mg/L + 10%
99.3%
0.002 mg/L + 10%
97.8%
0.006 mg/L + 10%
95.0%
0.006 mg/L + 10%
88%
0.015 mg/L + 10%
93.2%
11 + 1 NTU
98.7%
Certifi ed for up to 750 gallons (2,838 L); up to nine months
20 - 120 psi (1.4 - 8.2 bar)
33-100º F (0.6 - 37.8º C)
0.78 gpm (2.9 l/min.)
System tested and certifi ed by NSF International
against Standard 42 for the reduction of chlorine
taste and odor, particulate Class I and Standard 53
for the reduction of Lead, Lindane, Atrazine, Mercury,
Toxaphene, Cyst, Turbidity, and Asbestos.
29
Average
Max Permissible
Product Water
Product Water
Concentration
Concentration
0.05 mg/L
N/A
143,333
N/A
pts/mL
<1 MF/L
N/A
0.001 mg/L
0.003 mg/L
1 cyst/L
N/A
0.001 mg/L
0.010 mg/L
0.001 mg/L
0.010 mg/L
0.00004 mg/L
0.0002 mg/L
0.0003 mg/L
0.002 mg/L
0.0007 mg/L
0.002 mg/L
0.001 mg/L
0.003 mg/L
0.153 NTU
0.5 NTU
NSF
NSF Test
Reduction
Report
Requirements
> 50%
J-00056501
> 85%
J-00056506
> 99%
J-00056511
N/A
J-00056512
> 99.95%
J-00056513
N/A
J-00056515
N/A
J-00058784
N/A
J-00058969
N/A
J-00058785
N/A
J-00058783
N/A
J-00056531
N/A
J-00058972