(4) Detaching and refitting the high voltage PWB

Procedure
1. Remove the developing unit (See page 1-5-
11).
2. Remove the drum unit (See page 1-5-12).
3. Remove the cassette (See page 1-5-6).
4. Remove the outer covers (See page 1-5-3).
5. Remove the power source PWB (See page
1-5-22).
6. Turn the printer with the bottom side up.
7. Remove the stop ring.
8. Remove the DU holder.
9. Pull out the DU bush.
10. Remove the DU cover assembly.
Y 112480 - 6
DU cover assembly
Service Manual
Stop ring
DU holder
Figure 1-5-34
DU bush
Figure 1-5-35
1-5-25