Specifications

Model
Maximum Capacity
Topology
On-battery Output Waveform
Input Voltage Range
Input Frequency
Output Voltage Regulation
Communication Port
Data Line Surge Protection
Surge Energy Rating
Recharge Time to 90%
Operating Temperature
Storage Temperature
Relative Humidity
Audible Noise
Unit Dimensions (L×W×H), mm
Net Weight, kg
EMC/RFI Compatibility
Safety Certifications
*)
TS-B models only
Warranty
LIMITED WARRANTY
What the warranty covers:
We guarantee this product to be free from defects in material and workmanship during
the warranty period. If a product proves to be defective in material or workmanship
during the warranty period, we will at our sole option, repair or replace the product
with a like product.
How long the warranty is effective:
For accurate warranty period and conditions, please contact the local branch offices or
your dealers.
Who the warranty protects:
This warranty is valid only for the first consumer purchaser.
What the warranty does not cover:
1. Any product on which the serial number has been defaced, modified or
removed.
2. Damage, deterioration or malfunction resulting from:
a) Accident, misuse, neglect, fire, water, or other acts of nature, unauthorized
product modification, or failure to follow instructions supplied with the
product.
b) Repair or attempted repair by anyone not authorized by OPTI-UPS.
c) The fault is the result of accidental damage or damage in transit or
transportation, including but not limited to liquid spillage.
d) Removal or installation of the product.
e) Causes external to the product.
f)
Use of supplies or parts not meeting our specifications.
g) Normal wear and tear.
h) Any other cause which does not relate to a product defect.
3.
Removal, installation and set-up service charges.
Limitation of implied warranties:
There are no warranties, expressed or implied, which extend beyond the description
contained herein including the implied warranty of merchantability and fitness for a
particular purpose.
Exclusion of damages:
Our liability is limited to the cost of repair or replacement of the product. We shall not
be liable for:
1. Damage to other property caused by any defects in the product, damages based
upon inconvenience, loss of use of the product, loss of time, loss of profits, loss
of business opportunity, loss of goodwill, loss of data, loss of software, costs of
substitute equipment, interference with business relationships, claims by third
parties, or other commercial loss, even if advised of the possibility of such
damages.
2. Any other damages, whether incidental, consequential or otherwise.
3. Any claim against the customer by any other party.
Thunder Shield 1250(B)
600W
13.4 (14.8)
Thunder Shield 1700(B)
900W
Line-interactive
Simulated Sine Wave
110/120V or 220/230/240V ± 25%
50Hz/60Hz Auto Sensing
Rated voltage ± 5%
*)
RS232
*)
RJ11/RJ45
480 Joules
6 hours
0~40°C / 32~104℉
-20~60°C / -4~140℉
0 to 95% maximum, non-condensing
<40 dBA
382×130×192
CE
CE, UL, cUL

Troubleshooting

Problems
Possible Cause
Power switch not pressed
long enough
Battery voltage is less
UPS can't turn on,
than 10V
LED does not light
Load is less than 20W at
battery mode
PCB failure
Input power cord is loose
UPS always at battery
Busted input fuse
mode
Input voltage too high or
too low
PCB failure
Battery is not fully
charged or defective
Back up time too short
PCB failure
Buzzer continuously
Overload
beeping

Contact Information

OPTI-UPS USA:
OPTI-UPS Australia
Tel: +1-909-869-5700
& New Zealand:
Fax: +1-909-869-5730
Tel: +64-9-441-6470
info@opti-ups.com
Fax: +64-9-441-6490
www.opti-ups.com
info@opti-ups.com.au
www.opti-ups.com
OPTI-UPS Middle
OPTI-UPS Japan:
East:
Tel: +81-3-3629-5782
Tel: +9714-8819-838
Fax: +81-3-5682-0652
Fax: +9714-8819-938
japan@opti-ups.com
mea@opti-ups.com
www.opti-ups.com
www.opti-ups.com
Thunder Shield 2250(B)
1200W
15.9 (17.3)
Solution
Press the power switch for more
than 1 second until the UPS
turns on
Recharge the battery for 6 hours
by leaving the UPS plugged in
and the load disconnected from
the UPS.
Disable "No Load Shutdown
Function"
Call for service
Plug in the power cord firmly
Replace the fuse
Check input voltage
Call for service
Recharge the battery for 6
hours. If the problem is still
present, replace the battery.
Call for service
Remove some loads
OPTI-UPS Europe:
OPTI-UPS Germany:
Tel: +31-40-401-50-00
Tel: +49-2173-9377670
Tel: +31-40-262-80-57
Tel: +49-2173-9377671
Fax: +31-40-254-60-06
Fax: +49-2173-9377672
info@opti-ups.eu
info@opti-ups.de
www.opti-ups.com
www.opti-ups.com
OPTI-UPS Asia:
Tel: +886-2-2246-7272
Fax: +886-2-2246-7312
info@opti-ups.com.tw
www.opti-ups.com

Advertisement

loading