Programming the Water Softener.
OPTIONAL CONTROL SETTINGS
The controller display has several options and
features.
LOW SALT ALARM
The LOW SALT ALARM,
when enabled, will sound the
beeper when the DAYS TO
EMPTY value is 15 days or
less. To change this setting,
press and hold the MODE/SET
button for 3 seconds or hear
a beep. ON (factory default) or
OFF will flash in the display.
Press the UP
or DOWN
buttons to toggle this
feature ON or OFF. Press the
MODE/SET button to accept,
and the display will move to
the PRERINSE ON/OFF screen.
Press the UP
or DOWN
buttons to turn prerinse
on or off.
PRERINSE
If your water contains
sediment the prerinse
feature will remove sediment
from the resin bed prior to
regeneration.
Press the MODE/SET button
and the display will move to
Prerinse Time mode. In this
screen you can adjust the
duration of the prerinse by
pressing the UP
buttons. Press the MODE/
SET button to accept, and the
display will move to the Back
Wash screen.
or DOWN
BACKWASH AND FAST RINSE
If you experience salty tasting water after
regeneration, you may need to increase the
backwash and fast rinse times. The cycle times
during regenerations are determined by the
softener's electronic controller. However, you may
increase the backwash and fast rinse times. You
may add up to 10 minutes.
For Backwash, you can add
up to 10 minutes in 1 minute
increments, by pressing the
UP
button, or subtract
time by pressing the DOWN
button.
For Fast Rinse, press MODE/
SET and the display moves
to the add fast rinse time
screen. You can add up
to 10 minutes in 1 minute
increments, by pressing the
UP
button, or subtract
time by pressing the DOWN
button. Press the MODE/
SET button to accept, and the
display will move to the Run
Display screen.
SALT SAVER
When this feature is ON, the water softener
will operate at salt efficiencies of 4000 grains
of hardness per pound of salt or higher (May
recharge more often using smaller salt dosage
and less water). The softener is shipped with this
feature set OFF.
In the state of California: You must turn the Salt
Saver Feature ON. This may initiate more frequent
recharges. However, it will operate at 4,000 grains
per pound of salt.
To turn Salt Saver ON: Press the
Salt Saver button once until the
blue status light above the button
is ON.