Flavel EMBERGLOW Instruction Manual page 8

Coal effect balanced flue gas fire
Table of Contents

Advertisement

REMOVAL / RE-FITTING OF THE FUELBED
NOTE : The position of the fuel-bed components are critical to the
performance of the product. Therefore please ensure that the fuel-bed
components are positioned as described in the following section prior to
requesting a service call due to soot build up, poor flame pattern etc.
a)
Place the fuel-bed rear section centrally in the combustion chamber as
shown below in Fig. 5, ensuring
Fig. 5
b)
Fit the front ceramic coal form in front of the burner, as shown below in
Fig 6. Ensure that the front ceramic coal form is correctly located
behind the retaining brackets at the L/H & R/H ends.
Fig. 6
To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as "RCF waste". RCF waste is classed as a "stable", non
reactive hazardous waste and may be disposed of at a landfill licensed to
Retaining brackets for rear coal form
Retaining brackets
for front coal form