Indoor Unit - Panasonic CS-PC9DKV Service Manual

Table of Contents

Advertisement

CS-PC9DKV / CU-PC9DKV / CS-PC12DKV / CU-PC12DKV

Indoor Unit

Auto Switch
Button
Power Switch ON/OFF
When the remote control cannot be used or
for repairing and testing ,please use this
button.
Demonstration Mode
Keep pressing this button for 15seconds to start
or end the Demonstration Mode.
Signal Receiving Sound Control
Keep pressing this button for 10seconds to turn
on or turn off the signal receiving sound.
Operation Indication Lamps
Power (green)
Timer(orange)
Air quality
Operation Mode
Cooling/Soft Dry /Auto Operation/ Air circulation
Time Delay Safety Control
The unit will restart operation in 3-4
minutes after each pause.
Lights up in operation;
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Green
Orange
Red
National
7-Minutes Time Save Control
7-minutes automatic restarting at Cooling
Operation
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Indoor Fan Speed Control
High,Med,Low
Auto Fan Speed
Airflow Direction Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Airflow Direction Manual Control
Delayed On-timer Control
For cooling or soft dry mode, the unit
starts 15 minutes before the set time with
the remote control.
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-pc12dkvCu-pc9dkvCu-pc12dkv