O
'
M
peratOr
s
anual
STARTING THE MACHINE
Following the steps below will insure successful operation:
Read this manual completely before attempting to start the machine.
Check that the Motor/Burner switches are in the "OFF" position
Check the pump oil level and fill with SAE 30w non-detergent oil if needed.
Connect water hose to pump (or float tank if equipped). Turn on water source.
Connect the power cord to a properly grounded power source.
Turn the manual gas valve to "ON" position. Adjust incoming gas to 12" wc minimum for LP unit, 5" wc minimum for NG
(maximum14"wc or 1/2psi). The correct operating manifold pressure for natural gas is 3.5" wc and 11" wc for propane.
Attach high pressure hose to base of spray gun.
Install water nozzle at the end of wand, making sure it is clear of any obstructions.
Turn pump switch to "ON"
Pull trigger on gun until a steady stream of water comes out the nozzle. This purges any air in the system.
Check for leaks in the system and cycle trigger gun to insure bypass is adjusted correctly. Repair any leaks and correct
unloader adjustment if needed. Turn off machine before attempting any repairs.
Turn burner switch to "ON". Check for buner ignition.
Adjust thermostat to desired temperature appropriate to the task. Maximum temperature setting may not be needed.
Insert detergent siphoning tube into a DOT approved container and open the metering valve for detergent application.
WASHING TECHNIQUES
washing from bottom up increases dwell time of soap and lessens vertical streaks.
Turn soap metering valve "OFF" to purge system of soap
Rinsing with cold water from top down will retard detergent reaction which will enhance the rinsing performance.
wash at 30 to 60 degree angles to prevent splashback.
STOPPING THE MACHINE
Turn burner switch to "OFF". Allow water to discharge for a few minutes while cooling down.
Turn pump switch to "OFF".
Disconnect water source.
Pull gun trigger to release water pressure from system.
Disconnect wand & gun assembly.
wind up pressure hose on hose reel.
MAInTEnAncE PREcAuTIOns
Do not permit acidic, caustic or abrasive fluids to be pumped through system.
Periodically clean detergent inlet screen. This will ensure proper flow of water to the pump.
High mineral content in water may adversely affect your machine and may require the use of a water softener
to ensure proper operation.
NEVER run the pump dry under any circumtances. Doing so will cause exteme damage to the pump.
RAMTEQ
®
14275 northwest freeway
operating Instructions
Maintenance Instructions
houston, tX 77040
phone: 713.983.6000
faX: 713.983.6405
300-00010-03 8/05
p
age