Ramteq MVD Series Operator's Manual

Diesel engine / diesel fired

Advertisement

Quick Links

OPERATOR'S MANUAL
MVD Series
Diesel Engine / Diesel Fired
READ
THIS
MANUAL
This manual contains important information for the use and safe opera-
®
FOLLOW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING
ANY SERVICE OR MAINTENANCE PROCEDURE COULD RESULT IN
SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS; ALSO
DAMAGE TO THE MACHINE OR TO OTHER PROPERTY.
®
RAMTEQ
n
n
n
n

Advertisement

Table of Contents
loading

Summary of Contents for Ramteq MVD Series

  • Page 1 OPERATOR’S MANUAL MVD Series Diesel Engine / Diesel Fired READ THIS MANUAL This manual contains important information for the use and safe opera- ® FOLLOW ITS INSTRUCTIONS PRIOR TO OPERATING OR ATTEMPTING ANY SERVICE OR MAINTENANCE PROCEDURE COULD RESULT IN SERIOUS INJURY OR DEATH TO YOU OR OTHER PERSONS;...
  • Page 2: Included Parts

    Information in this operator ’s manual is subject to change without notice. RAMTEQ SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN. This operator ’s manual contains information protected by copyright. No part of this operator ’s manual may be photocopied or reproduced in any form without prior written consent from RAMTEQ.
  • Page 3 DO NOT permit water to freeze inside this machine. Pump and plumbing damage may occur. Use only recommended RAMTEQ ™ parts when servicing this machine. RAMTEQ ™ will not be held liable for any unauthorized modifications made to this machine. Any such action will void the warranty.
  • Page 4: Maintenance Precautions

    Place the wand into the antifreeze container and start engine, running machine until antifreeze appears from the end of the wand. Turn engine “OFF” and replace pressure nozzle. Coil up hose and move machine to storage area. ® RAMTEQ...
  • Page 5: Electrode Settings

    Change oil at every 500 Hour Intervals thereafter. UNLOADER ADJUSTMENT This RAMTEQ machine has the unloader correctly set at the the factory. Setting an unloader is a difficult job without the proper equipment and training. Should the need arise to change the unloader settings, please contact your local dealer.
  • Page 6: Location Guidelines

    Do not run the machine for more than two minutes with water flow shut off (by-pass mode). This will over heat the jetter and could cause personal injury. Do not run hot water thru this pump. Hot water will damage the pump, and will void the warranty. ® RAMTEQ...
  • Page 7 Plumbing Diagram on page 12 18 19 Plumbing Diagram on page 12 Control Box on page 10 ® RAMTEQ...
  • Page 8 Boot, red insulator, B&S 281223 591-00001-02 Battery 12v, Group U1,230 Crank Amps 270-00001-01 Nozzle, water, #3.5, 0 degr, quickconn 270-00001-02 Nozzle, water, #3.5, 15 degr, quickconn 270-00001-03 Nozzle, water, #3.5, 25 degr, quickconn 270-00001-04 Nozzle, water, #3.5, 40 degr, quickconn ® RAMTEQ...
  • Page 9 Electrode kit 7492 252-00009-01 Cad cell detector 51411 252-00011-01 Ignitor gasketr kit 51776U 252-00005-02 Ignitor w/ICB Specify Air tube assemblies 31802 256-00002-01 Flange mounting gasket 7435U 252-00005-01 Ignitor only 51663 252-00006-01 Ignitor Control Board 245-00007-14 Burner Nozzle, 1.75, 90A ® RAMTEQ...
  • Page 10 Fuse Holder 453-00005-01 Fuse, 25A, ATC-25 See page 8 for nozzles Dual lance,8107-1101,Comet 15*,43"SS 265-00002-01 275-00001-01 Gun,BE, 85.202.108 552-00003-03 QC plug,sp,3/8",nptf 554-00006-02 QC coupler socket,brs,1/4",nptm 270-00038-01 Nozzle,water,SS,1/4, soap,#40,15 degr 284-00007-02 Hose assy,50',4000PSI@250F,swivel 552-00004-03 QC plug,sp,3/8",nptf 554-00007-03 QC coupler socket,brs,3/8",nptf ® RAMTEQ...
  • Page 11 Comet Pump ZWD4040G Hollow Shaft Triplex Pump Repair Kits 221-00310-02 Check Valve Kit 5025.001.00 221-00302-07 Piston Seal Kit 5019.0064.00 221-00315-03 Oil Seals 0019.0095.00 221-00300-01 Piston Kit 2409.0071.00 221-00302-03 Pump Seal Kit 5019.0065.00 ® RAMTEQ...
  • Page 12 Pipe nipple, galv, 1/2 nptm x 2.50", sch 80 185-00001-01 Manifold, outlet 579-00004-04 Injector, detergent, BE#85.300.090 554-00007-03 QC coupler socket, brs, 3/8", nptf 285-00002-01 Tubing, clear, 1/4"ID, 3/8"OD 50 in 570-00002-01 Check valve, plastic, .25", w/screen 573-00001-01 Thermostat, 194 degree, 100438 518-00004-01 Plug, brs, 3/8 pipe ® RAMTEQ...
  • Page 13 ® RAMTEQ...
  • Page 14 Replace with valve kit Fluctuating Pressure Dir t or blockage in valves Clean or replace valve Pump sucking air Check water/detergent supply Worn plunger packing Replace packing kit Extended period in bypass Pull trigger gun for water flow Pump Head Overheating ® RAMTEQ...
  • Page 15: Manufacturer Limited Warranty

    Pumps void all warranties. LIMITATION OF LIABILITY RAMTEQ and Equipment Manufacturer liability for special, incidental, or consequential damages is expressly disclaimed. In no event shall any liability exceed the purchase price of the product in question.The warranty contained herein is in lieu of all other warranties express or implied, including any implied warranty of fitness for particular purpose.

Table of Contents