Unloader Adjustment - Ramteq XV LP Series Operator's Manual

Natural gas/propane
Table of Contents

Advertisement

O
'
M
peratOr
s
anual
EXchAnGER cOIl MAInTEnAncE
Hard water conditions may eventually cause clogging in the heat exchanger coil if left unattended.
Scale deposits will compromise the heating efficiency and produce an unsafe condition over time.
It may be necessary to descale coil.
Scale buildup from certain detergents may eventually clog up the heat exchanger coil causing an
unsafe condition. Use only
Black carbon deposits that collect on the outside wall of the heat exchanger coil may be a result of
using a poor grade of fuel or improper burner operation. Heating fuel should be void of water and
sediments to eliminate the possibility of sooting and compromising the efficiency of the coil.
MOVING, STORAGE
 Place machine in covered area when not in use to protect from elements.Protect machine from
freezing in cold temperatures by storing in a heated location.
WINTERIZING
 Non-float Tank Machines: To protect the machine from freezing temperatures while
storing or transporting, connect short length of garden hose (approximately 3 ft.) to
water inlet connection on machine. Remove the pressure nozzle from the wand and
insert the short garden hose end into a container of antifreeze. Place the wand into the
antifreeze container and start engine running machine until antifreeze appears from the
end of the wand. Turn engine "OFF" and replace pressure nozzle. Coil up hose and
move machine to storage area.
 Float Tank Machines: Pour antifreeze into float tank and remove water nozzle from end
of wand and carefully insert into opening of float tank. Start machine and run until
antifreeze water mixture has circulated throughout the machine returning back to the
float tank.
PUMP MAINTENANCE
 Fill crankcase to dot on oil gauge window per specifications with the specific oil created by the pump
manufacturer (i.e. General Pump Oil). Ensure the right oil for specific pump as it may vary.
 Change oil after 40 Hour Break-in Period.
 Change oil every Three Months or at 500 Hour Intervals thereafter.

unlOAdER AdjusTMEnT

All RAMTEQ machines have the unloader
correctly set at the the factory. Setting an
unloader is a difficult job without the proper
equipment and training. Should the need arise
to change the unloader settings, please contact
your local distributor.
RAMTEQ
®
14275 northwest freeway
FAIluRE TO MAInTAIn hEAT EXchAnGER cOIl
MAy REsulT In A sTEAM EXPlOsIOn WhIch
MAy cAusE sERIOus InjuRy OR dEATh.
W ARNING
recommended detergents for better cleaning efficiency.
chAnGInG ThE unlOAdER sETTInGs WIThOuT ThE PROPER
EQuIPMEnT And TRAInInG MAy REsulT In nOn-WARRAnTy
dAMAGE TO ThE PuMP.
W ARNING
houston, tX 77040
Sutner
Unloader
phone: 713.983.6000
Pulsar
Unloader
faX: 713.983.6405
300-00010-03 8/05
p

age

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xv ng series