LOCATION GUIDELINES
 Locate the machine on a solid and level surface so that engine and pump crankcase oil lubricate components properly.
Avoid areas where water can build up in the working area. Possible injury can occur caused by the surface becoming
slippery from water build up.
 Locate the machine in a well-ventilated area and away from flammable materials or fumes. Be sure ventilation warnings
are observed. Keep pressure washer at least 18" away from flamable materials.
 Locate the machine so the operator has easy access to the pressure washer and its controls. Locate the machine so that
it is protected from external damage.
 To prevent damage and excessive hose wear, locate the pressure washer so that the hose does not cross traffic areas
STARTING THE MACHINE
Following the steps below will insure successful operation:
 Read this manual completely before attempting to start the machine.
 Check that the Motor/Burner switches are in the "OFF" position
 Check the diesel tank and fill with a good grade of diesel fuel #1, #2 or kerosene.
 Check the pump oil level and fill with SAE 30w non-detergent oil if needed.
 Connect water hose to pump (or float tank if equipped). Turn on water source.
 Connect the power cord to a properly grounded power source.
 Attach high pressure hose to base of spray gun.
 Install water nozzle at the end of wand, making sure it is clear of any obstructions.
 Turn pump switch to "ON"
 Pull trigger on gun until a steady stream of water comes out the nozzle. This purges any air in the system.
 Check for leaks in the system and cycle trigger gun to insure bypass is adjusted correctly. Repair any leaks and correct
unloader adjustment if needed. Turn off machine before attempting any repairs.
 Turn burner switch to "ON". Check gor buner ignition.
 Adjust thermostat to desired temperature appropriate to the task. Maximum temperature setting may not be needed.
 Insert detergent siphoning tube into a DOT approved container and open the metering valve for detergent application.
WASHING TECHNIQUES
 washing from bottom up increases dwell time of soap and lessens vertical streaks.
 Turn soap metering valve "OFF" to purge system of soap
 Rinsing with cold water from top down will retard detergent reaction which will enhance
the rinsing performance.
 wash at 30 to 60 degree angles to prevent splashback.
STOPPING THE MACHINE
 Turn burner switch to "OFF". Allow water to discharge for a few minutes while cooling down.
 Turn pump switch to "OFF".
 Disconnect water source.
 Pull gun trigger to release water pressure from system.
 Disconnect wand & gun assembly.
 wind up pressure hose on hose reel.