Unvented hot water cylinder
Table of Contents

Advertisement

Max direct kW rating @240v
Direct heat time (based on max kW rating in mins)
Heat loss (kWh in 24h)
Weight full (kg)
Weight empty (kg)
Max supply pressure
Max design pressure
Max operating pressure (PRV)
Max expansion vessel charge pressure
Expansion relief valve setting
T&P valve setting
Table 2: Technical data - Direct
Notes:
1. Direct cylinders tested in accordance with EN 50440 for efficiency
parameters
2. Heat up time from cold through 45°C, based on a flow temperature of
80°C +/- 2°C & normal volume.
6
3
3
3
3
99
121
152
173
1.14
1.25
1.45
1.63
123
145
178
199
23
25
28
29
1.6MPa (16 bar)
0.8MPa (8 bar)
0.35MPa (3.5 bar)
0.35MPa (3.5bar)
0.6MPa (6 bar)
1.0MPa (10 bar)/90°C
3
3
9
3
215
257
88
310
1.91
2.22
2.22
2.52
246
295
295
355
36
45
45
55
9
105
2.52
355
55

Hide quick links: