The Model 6115-01, Model 6116-01 and Model 6119-01 High Voltage Power Supply has four
output voltages of which three are adjustable.
1.
25,000 Volts (Anode Voltage)
2.
7,000 Volts (Focus Voltage)
3.
450 Volts (Grid 2 Voltage)
The anode and G2 Voltages should be factory preset to their respective values. However, the
focus voltage must always be adjusted when either the CRT or the High Voltage Power
Supply are replaced.
6115 - 6120 Operation and Maintenance Manual
©EDL Displays, Inc. January 1997
35