Heatrae Sadia PremierPlus PES170D Installation And User Manual page 3

Solar unvented hot water cylinder
Table of Contents

Advertisement

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION
THE INFORMATION CONTAINED IN THESE INSTRUCTIONS DETAILS HOW TO CONNECT THE
PREMIER PLUS SOLAR CYLINDER TO A SOLAR PRIMARY CIRCUIT. OTHER CONTROLS WILL
BE NECESSARY TO PROVIDE CONTROL OVER THE SOLAR PRIMARY CIRCUIT, REFER TO THE
INSTRUCTIONS SUPPLIED WITH THE SOLAR CONTROLS AND ANCILLARY EQUIPMENT FOR
DETAILS OF HOW TO INTEGRATE THEM WITH THE PREMIER PLUS SOLAR CYLINDER.
GENERAL REQUIREMENTS
IMPORTANT: THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE
AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF
EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISORY OR INSTRUCTION
CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS
INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER
MAINTENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION.
WARNING: Do not switch on if there is a possibility that the water in the heater is frozen.
OPERATIONAL SUMMARY (Indirect models in conformance with BS EN 12897:2006)
Maximum mains water supply pressure (to 3 bar pressure reducing valve)
Operating pressure (pressure reducing valve set pressure - non adjustable)
Expansion vessel pressure
Expansion relief valve setting
T&P relief valve setting
Primary coil operating pressure (max)
Immersion heater rating (a.c. supply only)
Primary Coil ratings
(Based on a primary flow rate of 15L/min
and a flow temperature of 80 °C)
Pressure drop across coils
Storage capacity
Weight when full
Note: Although the primary coil pressure rating is 1.0Mpa (10 bar) the 2 port zone valve supplied with the
cylinder is only rated 0.86MPa (8.6 bar). If the cylinder is to be plumbed into a system delivering 1.0MPa (10
bar) a suitable 2 port zone valve will have to be sourced.
See Table 2, Page 4
See Table 2, Page 4
1.6MPa (16 bar)
0.35MPa (3.5 bar)
0.35MPa (3.5 bar)
0.6MPa (6 bar)
1.0MPa/90 °C (10 bar)
1.0MPa (10 bar)
3kW @ 240V 50Hz
2.8kW @ 230V 50Hz
See Table 2, page 4
0.02MPa (0.2bar)
3

Hide quick links: