Safety Information
Safety Precautions . . . . . . . . . . . . . . . .3
How to Connect Electricity . . . . . . . .3
Use of Extension Cords . . . . . . . . . . .4
Use of Adapter Plugs . . . . . . . . . . . . .4
Operating Instructions
About the Controls . . . . . . . . . . . . .5, 6
Care and Cleaning
Grille and Case . . . . . . . . . . . . . . . . . . .7
Outdoor Coils . . . . . . . . . . . . . . . . . . .7
Air Filter . . . . . . . . . . . . . . . . . . . . . . . .7
Installation Instructions
Window Installation–5000 BTU
Model (HSV05) . . . . . . . . . . . .8, 9–12
Window Installation–7000, 8000,
and 10,000 BTU Models (HSV07,
HSV08, and HSV10) . . . . . .8, 13–17
Window Installation–12,000, 14,000,
18,000 and 24,000 BTU Models
(HSV12, HSV14, HSV18, and
HSV24) . . . . . . . . . . . . . . . . . .8, 18–23
Through the Wall
Installation–Optional
All Models . . . . . . . . . . . . . . . . . . . . . .24
Owner's Manual
and Installation Instructions
Air Conditioners
www.geappliances.com
Troubleshooting Tips
Before You
Call For Service . . . . . . . . . . . . . . . . .25
Normal Operating Sounds . . . . . . .25
Customer Service
Product Registration . . . . . . .2, 29, 30
Warranty . . . . . . . . . . . . . . . . . . . . . . .31
Service Telephone
Numbers . . . . . . . . . . . .2, Back Cover
HSV05
HSV07
HSV08
HSV10
HSV12
HSV14
HSV18
HSV24
39-7388-1 12-99 JR
E DB68-00954A(2)

Advertisement

Table of Contents
loading

Summary of Contents for Hotpoint HSV05

  • Page 1 Air Filter ......7 Installation Instructions Window Installation–5000 BTU Model (HSV05) ... .8, 9–12 Window Installation–7000, 8000, and 10,000 BTU Models (HSV07, HSV08, and HSV10) .
  • Page 2: For Your Records

    GE & You, A Service Partnership. IMPORTANT! Fill out the Consumer Product Registration Card. Two easy ways to register your appliance! Through the internet at www.geappliances.com Complete and mail the enclosed Product Registration Card FOR YOUR RECORDS Write the model and serial numbers here: You can find them on a label on the side of the air conditioner.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury. SAFETY PRECAUTIONS Use this appliance only for its intended Turn the mode control to OFF and unplug purpose as described in this Owner’s your air conditioner before making any...
  • Page 4: Use Of Extension Cords

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! USE OF EXTENSION CORDS – 115-Volt models only Because of potential safety hazards under certain CAUTION: conditions, we strongly recommend against the use of an extension cord. DO NOT use an extension cord with any of However, if you must use an extension cord, the 230/208 volt models.
  • Page 5: About The Controls On The Air Conditioner

    About the controls on the air conditioner. Features and appearance will vary. HIGH HIGH COOL COOL COOL COOL COOL COOL MED COOL COOL MODE CONTROLS Your model will have one of the above type controls. TEMP CONTROLS Your model will have one of the above type controls. Controls Mode Controls Temp Controls...
  • Page 6 About the controls on the air conditioner. Additional controls and important information. Energy Saver (on some models) OFF — The fan runs all the time, while the The energy saver switch controls the fan. compressor cycles on and off. ON —The fan and compressor cycle on and off together.
  • Page 7: Care And Cleaning Of The Air Conditioner

    Care and cleaning of the air conditioner. Grille and Case Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not from the wall outlet before cleaning. use bleach or abrasives. Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly.
  • Page 8: Before You Begin

    Preparing to install the air conditioner–All models. Read these instructions completely and carefully. Before You Begin NOTE TO INSTALLER: Leave these instructions with CAUTION: the air conditioner after installation is completed. Do not, under any circumstances, cut or remove the third (ground) prong from the NOTE TO CONSUMER: Keep this Owner’s Manual power cord.
  • Page 9: Tools You Will Need

    Window Installation Instructions for 5000 BTU Units (model HSV05) Parts Included Window sash seal Top mounting rail Foam top window gasket Top mounting rail seal strip Left accordion HSV05 panel Right air conditioner accordion panel Security bracket (3) Type A (9)
  • Page 10: Storm Window Requirements

    Window Installation Instructions for 5000 BTU Units (model HSV05) Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow window.
  • Page 11: Prepare The Air Conditioner

    Prepare the Air Conditioner Remove the backing from the top mounting Loosen the lower screw on each side of the case rail seal strip and attach it to the bottom of the and hook a security bracket on each side. top mounting rail.
  • Page 12 Window Installation Instructions for 5000 BTU Units (model HSV05) Install the Air Conditioner in the Window Cut the window sash seal to the window Extend the left and right accordion panels width and stick the adhesive side to the to the vertical window sashes and attach bottom of the sash.
  • Page 13 Window Installation Instructions for 7000, 8000, and 10,000 BTU Units (models HSV07, HSV08, and HSV10) Read the section Preparing to Install the Air Conditioner before beginning. Top mounting rail Window sash seal Left accordion Foam top panel window gasket Top mounting rail seal strip Right accordion...
  • Page 14 Window Installation Instructions for 7000, 8000, and 10,000 BTU Units (models HSV07, HSV08, and HSV10) Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- All supporting parts must be secured to firm wood, masonry or metal. hung window.
  • Page 15 Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case. Slide the air conditioner from the case by Keep these for later use. gripping the base pan handle and pulling forward while bracing the case. Remove packing cardboard and tape if present.
  • Page 16 Window Installation Instructions for 7000, 8000, and 10,000 BTU Units (models HSV07, HSV08, and HSV10) Install the Case in the Window Cut the window sash seal to the window width Locate the 3 screw holes along the bottom front and stick the adhesive side to the bottom of edge of the case.
  • Page 17 Install the Air Conditioner in the Case Slide the air conditioner into the case. Attach the front grille to the case by inserting the Reinstall the 2 screws removed earlier on each tabs on the grille into the slots on the front of the side of the case.
  • Page 18 Window Installation Instructions for 12,000, 14,000, 18,000, and 24,000 BTU Units (models HSV12, HSV14, HSV18, and HSV24) Read the section Preparing to Install the Air Conditioner before beginning. Parts Included Window sash seal Top mounting rail Left accordion Foam top panel Support rail (2) window gasket...
  • Page 19 Read completely, then follow step-by-step. Window Requirements These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow ″...
  • Page 20 Window Installation Instructions for 12,000, 14,000, 18,000, and 24,000 BTU Units (models HSV12, HSV14, HSV18, and HSV24) Remove the Air Conditioner From the Case Remove the 2 screws on each side of the case. Slide the air conditioner from the case by Keep these for later use.
  • Page 21 Prepare the Window Cut the window sash seal to the window width Mark the centerline of the stool. Measure and and stick the adhesive side to the bottom of mark the locations for the support assemblies ″ from both sides of the centerline. the sash.
  • Page 22 Window Installation Instructions for 12,000, 14,000, 18,000, and 24,000 BTU Units (models HSV12, HSV14, HSV18, and HSV24) Install the Case in the Window Carefully slide the case into the window until Extend the left and right accordion panels to the bottom mounting rail drops into the the vertical window sashes and attach the top channels in the support assemblies.
  • Page 23 Install the Air Conditioner in the Case Slide the air conditioner into the case. Attach the front grille to the case by inserting the Reinstall the 2 screws removed earlier on each tabs on the grille into the slots on the front of the side of the case.
  • Page 24 Through the Wall Installation Instructions–Optional for All Models The case may be installed through the wall in both existing and new construction. Read completely, then follow step-by-step. IMPORTANT Through the wall installation is not appropriate if any of the side louvers in the case will be obstructed by the wall.
  • Page 25: Normal Operating Sounds

    Before you call for service… Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do Air conditioner The air conditioner • Make sure the air conditioner plug is pushed does not start is unplugged.
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28 Notes...
  • Page 29 GE Service Protection Plus ™ GE, a name recognized worldwide for quality and dependability, offers you Service Protection Plus ™ —comprehensive protection on all your appliances— No Matter What Brand! We’ll Cover Any Appliance. Benefits Include: • Backed by GE Anywhere.
  • Page 30: Serial Number

    Consumer Product Ownership Registration Dear Customer: Thank you for purchasing our product and thank you for placing your confidence in us. We are proud to have you as a customer! Follow these three steps to protect your new appliance investment: 1 2 3 Complete and mail After mailing the...
  • Page 31: Air Conditioner Warranty

    Air Conditioner Warranty All warranty service provided by our Factory Service Centers, or an authorized Customer Care technician. For service, ® call 800-GE-CARES. For The Period Of: We Will Replace: One Year Any part of the air conditioner which fails due to a defect in materials or workmanship. From the date of the During this full one-year warranty, we will also provide, free of charge, all labor original purchase...
  • Page 32: Service Telephone Numbers

    Service Telephone Numbers. ® GE Answer Center 800.626.2000 The GE Answer Center® is open 24 hours a day, 7 days a week. In-Home Repair Service 800-GE-CARES (800-432-2737) Expert GE repair service is only a phone call away. Special Needs Service 800.626.2000 800-TDD-GEAC (800-833-4322) GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons...

This manual is also suitable for:

Hsv08Hsv12Hsv14Hsv07Hsv18Hsv24 ... Show all