PROBLEM
Unit does not ignite when water goes
through the unit.
The fan motor is still spinning after
operation has stopped.
Abnormal sounds come from the unit. • Contact the manufacturer at 1-877-737-2840.
~ REMOTE CONTROLLER: 9007603005
PROBLEM
Remote controller does not display
anything when the power button is
turned on.
An ERROR code is displayed.
PROBLEM
How are the unit numbers assigned?
~ WATER HEATER ~
• Is the flow rate over 0.5 GPM? (p. 30)
• Check for the filter on cold water inlet. (p. 34)
• Check for reverse connection and cross connection.
• If you use the remote controller, is the power button
turned on? (p. 30)
• This is normal. After operation has stopped, the fan
motor keeps running for 35 seconds in order to re-
ignite quickly, as well as push all exhaust gas out of
the flue.
(TM-RE30) (OPTIONAL) ~
Press the ON/OFF button.
If the lamp lights up ⇒
• This is normal. When the unit has not operated for
five minutes or more, the display turns off to
converse energy.
If the lamp does not light ⇒
• Make sure the unit gets power supply.
• Make sure the connection to the unit is correct.(p. 21)
• Please see the p. 37.
~ EASY-LINK SYSTEM ~
• For an Easy-Link system, other than the Parent Unit
(which is always labeled #1), all the other units (the
Child units) are numbered randomly.
• To check which numbers are assigned to which
units, push the button on the computer board of a
unit as shown below.
displayed on the 7-Seg LED.
Unit# display
button
7-Seg LED
- 36 -
POSSIBLE SOLUTIONS
POSSIBLE SOLUTIONS
POSSIBLE SOLUTIONS
The unit number will be