Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when G starts to flash, or at least
once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction
motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press F and hold for approximately 5 seconds:
• Button B flashes twice -- A.C. Filter saturation alarm ACTIVATED
• Button B flashes once -- A.C. Filter saturation alarm DEACTIVATED
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press button G and hold for approximately 5 seconds (See
paragraph on Use).
Changing the Filter
• Open the comfort panels pulling them downwards.
• Remove grease filters.
• Remove the saturated activated charcoal filters, as indicated
(A).
• Fit the new filters, as indicated (B).
• Replace the metal grease filters.
• Close the comfort panels.
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Refit the Support, fixing it in place with the two screws re-
moved as above.
EN
Lighting
LIGHT REPLACEMENT