2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effective- ness has been reduced, for example, by cracks or deep scratches. 3) Do not look directly at the lamp while lamp is on. Declaration of CE conformity COEF srl. Via Albinatico, 80-82 / ITALY 51019 Ponte Buggianese (Pistoia)
The lamp must be replaced if it has been damaged or thermally deformed. Clean regularly the in-out ventilating grilles. Do not handle the spot by taking it by the head, but always by using the special handles. Pag. 4 http://www.coef.it info@coef.it...
Page 5
You must control that the two filters completely cover the overall of the air entrance. http://www.coef.net - info@coef.it Pag. 5...
• DOWN to go backward in the selected options • UP to go forward in the selected options • ENTER to confirm the selected options DISPLAY Shows the various menus and the selected options. Pag. 6 http://www.coef.it info@coef.it...
Page 7
Down and UP. A control of the memory will be run and all the default settings will be stored: the display will then show Init. If the memory is damaged, the display will show the message FAIL. To go back to the op- tions without making any change, press the MENU button. http://www.coef.net - info@coef.it Pag. 7...
Page 9
EXAMPLE 1: connection controller-spot with 1 DMX 512 output LAST SPOT SPOT SPOT SPOT CONTROLLER DMX TERMINATION RESISTOR EXAMPLE 2: connection controller-spot to one DMX 512 output over 150mts long LAST SPOT SIGNAL AMPLIFIER SPOT CONTROLLER DMX TERMINATION RESISTOR http://www.coef.net - info@coef.it Pag. 9...
Page 10
EXAMPLE OF CONNECTION AND SETTING OF 4 “SIRIO RAY” IN SYNCHRO - MODE MASTER SLAVE SLAVE SLAVE WARNING: the cables are the same as the DMX standard cable EXAMPLE OF CONNECTION AND SETTING OF 4 “SIRIO RAY” IN INDIPENDENT AUTO - MODE MASTER MASTER MASTER MASTER Pag. 10 http://www.coef.it info@coef.it...
• Description of the problem and the troubleshooting procedures that you have performed so far to diagnose and resolve the fault. You can contact your authorized COEF dealer or directly COEF Technical Service. (fax. +39.0572.636535 - e-mail: technical@coef.it) Appendix “C” - Table A1 http://www.coef.net - info@coef.it...
Page 12
DATA LINK (DMX 512) TROUBLESHOOTING Appendix “C” - Table A2 Pag. 12 http://www.coef.it info@coef.it...
Check the main fuse, if it is blown check VR1 (normally it has a resistance = ¥). If it is in short circuit you must change it. Check D1 (Bridge Rectifier), if it is ok check C65. If the fuse is still blown, change U11 http://www.coef.net - info@coef.it Pag. 13...
Page 14
THE COMPLETE LIST OF DMX VALUES APPENDIX -A- THE COMPLETE LIST OF THE AVAILABLE GAMES APPENDIX -B- Pag. 14 http://www.coef.it info@coef.it...
Need help?
Do you have a question about the Sirio RAY 1200 02B014 and is the answer not in the manual?
Questions and answers