Drain System

The washer can be installed using the standpipe drain system (floor or wall), the laundry tub
drain system, or the floor drain system. Select the drain hose installation method you need.
See "Tools and Parts."
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum
carry-away capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 30" (76.2 cm) high and no higher than 96" (2.4 m)
from the bottom of the washer.
A
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be
at least 30" (76.2 cm) above the floor.
Floor drain system (view D)
The floor drain system requires a siphon break that may be purchased separately. See "Tools
and Parts."
The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer.
Additional hoses might be needed.
C
30" min.
(76.2 cm)
B
26" min.
(66 cm)
30" min.
(76.2 cm)
D

Electrical Requirements

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-
delay fuse or circuit breaker is recommended. It is recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong,
grounding-type outlet, grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility and obligation of the
customer to have the properly grounded outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is recommended that a qualified
electrician determine that the ground path is adequate.